Substation Automation and IED Data

This dataset provides comprehensive, time-stamped records of Intelligent Electronic Device (IED) operations within digital substations, including relay settings, fault events, system logs, and IEC 61850 GOOSE message exchanges. It enables detailed analysis of substation automation, operational reliability, and event traceability for power grid monitoring and optimization.

  • opened 6 times
  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Grid reliability and fault analysis

Sample rows

preview · 8 of 105 rows · all 27 columns
ied_idstringied_manufacturerstringfault_current_peakfloatsubstation_namestringsubstation_idstringied_modelstringied_firmware_versionstringrelay_setting_idstringrelay_typestringrelay_setting_valuefloatrelay_setting_unitstringrelay_setting_timestampdatetimefault_record_idstringfault_typestringfault_start_timedatetimefault_end_timedatetimefault_duration_secondsfloatevent_log_idstringevent_typestringevent_timestampdatetimegoose_message_idstringgoose_publisher_ied_idstringgoose_subscriber_ied_idstringgoose_message_typestringgoose_message_timestampdatetimeevent_descriptionstringgoose_message_payloadstring
IED-000001Schweitzer Engineering Labs2380.2Green ValleySS-001SEL-751AFW-3.21RS-00001overcurrent1168.7A2024-04-01T08:10:00ZFR-00001phase-to-ground2024-04-01T08:18:27Z2024-04-01T08:19:45Z78EL-00001trip2024-04-01T08:19:50ZGM-00001IED-000001IED-000002trip2024-04-01T08:19:52ZTrip due to phase-to-ground fault detected by overcurrent relay.GOOSE trip: phase-to-ground fault, relay tripped.
IED-000002ABB1450.7Central CitySS-002ABB-REF615FW-2.14RS-00002distance9.3Ohm2024-04-02T09:00:00ZFR-00002three-phase2024-04-02T09:07:18Z2024-04-02T09:08:01Z43EL-00002alarm2024-04-02T09:08:04ZGM-00002IED-000002IED-000003block2024-04-02T09:08:06ZAlarm: abnormal impedance detected by distance relay.GOOSE block: distance relay blocking due to alarm.
IED-000003General Electric1950.5SouthpointSS-003GE-869FW-1.87RS-00003differential0.075A2024-04-03T10:15:00ZFR-00003three-phase2024-04-03T10:17:33Z2024-04-03T10:17:56Z23EL-00003trip2024-04-03T10:18:00ZGM-00003IED-000003IED-000004trip2024-04-03T10:18:02ZTrip: three-phase fault detected by differential relay.GOOSE trip: three-phase differential fault.
IED-000004Schweitzer Engineering Labs800.1Green ValleySS-001SEL-710FW-2.90RS-00004voltage122.7V2024-04-04T11:00:00ZFR-00004phase-to-ground2024-04-04T11:09:13Z2024-04-04T11:10:15Z62EL-00004alarm2024-04-04T11:10:20ZGM-00004IED-000004blankstatus2024-04-04T11:10:22ZAlarm: undervoltage detected, phase-to-ground fault.GOOSE status: undervoltage alarm phase-to-ground.
IED-000005Mitsubishi Electric50.2HillcrestSS-004Mitsubishi-PRG600blankRS-00005frequency49.98Hz2024-04-05T12:10:00ZFR-00005other2024-04-05T12:15:27Z2024-04-05T12:15:41Z14EL-00005reset2024-04-05T12:15:45ZGM-00005IED-000005blankstatus2024-04-05T12:15:47ZReset: frequency fault cleared, relay reset.GOOSE status: frequency relay reset.
IED-000006Siemens1700.4RiverbendSS-005Siemens-7SJ85FW-4.51RS-00006distance0Ohm2024-04-06T13:05:00ZFR-00006phase-to-phase2024-04-06T13:10:44Z2024-04-06T13:11:20Z36EL-00006alarm2024-04-06T13:11:25ZGM-00006IED-000006IED-000007block2024-04-06T13:11:27ZAlarm: zero impedance detected by distance relay.GOOSE block: distance relay zero impedance alarm.
IED-000007Schweitzer Engineering LabsblankEastfieldSS-006SEL-351SFW-5.03RS-00007other-8.7A2024-04-07T14:30:00ZFR-00007other2024-04-07T14:32:13ZblankblankEL-00007test2024-04-07T14:32:16ZGM-00007IED-000007blankother2024-04-07T14:32:18ZTest: relay type other, negative setting for edge case.blank
IED-000008ABB2001.8North RidgeSS-007ABB-REL670FW-3.08RS-00008distance16.9Ohm2024-04-08T15:10:00ZFR-00008phase-to-phase2024-04-08T15:16:59Z2024-04-08T15:17:22Z23EL-00008alarm2024-04-08T15:17:25ZGM-00008IED-000008IED-000009block2024-04-08T15:17:27ZAlarm: distance relay phase-to-phase fault detected.GOOSE block: phase-to-phase distance fault.

What the 105 rows show

from the 105-row sample

Schneider Electric (ied manufacturer) stands out: mean fault_current_peak is 88.4, against 1,319 for the rest.

  • 1,430median fault_current_peak
  • 4relay setting units
  • 4fault types
  • 4goose message types
  • 5event types
  • 6relay types
Mean fault_current_peak by ied_manufacturer87 rows
01,0002,0001,834Schw…23 ro…727.6ABB17 ro…1,642Siem…16 ro…896.7Gene…12 ro…88.4Schn…11 ro…790.4Mits…3 rows1,263Eaton5 rows
fault_current_peak87 rows, in bands of 500
02040311132812201,5003,000fault_current_peak →

Median 1,430, from 0.0 to 2,690.

substation_name105 rows · top 10 of 33 values
  1. Green Valley10
  2. Eastfield8
  3. Southpoint7
  4. Hillcrest7
  5. Central City6
  6. Meadowbrook6
  7. Lakeview6
  8. Westwood5
  9. North Ridge4
  10. Riverbend3
27 columns by typefrom the column list below
  • string 19
  • float 3
  • datetime 5

Columns

27 columns in three groups
blueprint · 27 columns
columntypedescriptionexample
Text 19 columns
ied_idstringUnique identifier for the Intelligent Electronic Device (IED)uniqueIED-000001
substation_idstringUnique identifier for the substation where the IED is locatedSS-001
substation_namestringName of the substationGreen Valley
ied_modelstringModel name or number of the IEDSEL-751A
ied_manufacturerstringManufacturer of the IED7 manufacturersABB
ied_firmware_versionstringFirmware version running on the IEDoptionalFW-3.21
relay_setting_idstringUnique identifier for the protective relay setting recorduniqueRS-00001
relay_typestringType of protective relay (e.g., overcurrent, distance, differential)6 valuesovercurrent
relay_setting_unitstringUnit of measurement for the relay setting value (e.g., A, V, s)4 unitsA
fault_record_idstringUnique identifier for the fault recorduniqueFR-00001
fault_typestringType of fault detected (e.g., phase-to-ground, phase-to-phase)phase-to-ground · phase-to-phase · three-phase · otherphase-to-ground
event_log_idstringUnique identifier for the event log entryuniqueEL-00001
event_typestringType of event (e.g., trip, alarm, reset, test)trip · alarm · reset · test · othertrip
event_descriptionstringDetailed description of the eventoptionalTrip due to phase-to-grou…
goose_message_idstringUnique identifier for the IEC 61850 GOOSE messageuniqueGM-00001
goose_publisher_ied_idstringIED ID of the publisher of the GOOSE messageIED-000001
goose_subscriber_ied_idstringIED ID of the subscriber of the GOOSE messageoptionalIED-000002
goose_message_typestringType of GOOSE message (e.g., trip, block, status)trip · block · status · othertrip
goose_message_payloadstringPayload or content of the GOOSE message (as a string)optionalGOOSE trip: phase-to-grou…
Numbers 3 columns
relay_setting_valuefloatConfigured value for the relay setting1168.7
fault_duration_secondsfloatDuration of the fault in seconds0 or more · optional78
fault_current_peakfloatPeak current measured during the fault (in Amperes)0 or more · optional2380.2
Dates and times 5 columns
relay_setting_timestampdatetimeDate and time when the relay setting was applied2024-04-01T08:10:00Z
fault_start_timedatetimeTimestamp when the fault started2024-04-01T08:18:27Z
fault_end_timedatetimeTimestamp when the fault endedoptional2024-04-01T08:19:45Z
event_timestampdatetimeDate and time when the event occurred2024-04-01T08:19:50Z
goose_message_timestampdatetimeTimestamp when the GOOSE message was sent2024-04-01T08:19:52Z

Use it for

  • median fault c…1,43087 rowsmean fault current pe…1.8kSchw…727.6ABB1.6kSiem…896.7Gene…

    An energy dashboard

    Fault_current_peak by ied_manufacturer and a breakdown of substation_name. Excel, Power BI or Tableau.

  • Why do the 11 Schneider Electric rows have a mean fault_current_peak of 88.4?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable ieds with substation_id, substation_name and ied_model to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 27 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset105 rows27 columns
Yours1,000 rows27 columns

blueprint · substation-automation-and-ied-data

Behind this dataset

Same schema. As many rows as you need.

These 105 rows came out of a blueprint — 27 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • IED ID unique per device
  • Device type: protective relay, RTU, merging unit, bay controller
  • Communication protocol: IEC 61850, DNP3, Modbus, IEC 60870-5-104
  • GOOSE (Generic Object-Oriented Substation Event) messages
  • Sampled Values (SV) for process bus architecture
  • Fault records with oscillography data
  • Sequence of events (SOE) with sub-second timestamps
  • Relay settings: pickup, time delay, coordination curves
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
substation-automation-and-ied-data

What should your data show?

Preview 20 rows free
No signup. No card.