Protective Relay Schemes and Settings

This dataset provides comprehensive information on protective relay schemes used in electrical power systems, including relay types, settings, coordination curves, zones of protection, fault clearing times, and backup protection details. It is ideal for reliability analysis, asset management, and optimization of protection coordination in substations and transmission networks.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Protection coordination and reliability analysis in power systems

Sample rows

preview · 8 of 103 rows · all 21 columns
relay_scheme_idstringrelay_typestringsetting_pickup_currentfloatbackup_protection_presentbooleanbackup_relay_typestringrelay_manufacturerstringrelay_modelstringsetting_time_delayfloatcoordination_curve_typestringzone_of_protectionstringprimary_element_protectedstringfault_clearing_timefloatbackup_clearing_timefloatdate_commissioneddatelast_setting_review_datedatesystem_voltage_levelfloatlocation_substationstringlocation_citystringlocation_statestringlocation_countrystringscheme_descriptionstring
RS-101-Aovercurrent158.7truedistanceSchneider ElectricSEP-34210.31IECfeederdistribution cable0.190.442017-06-122023-08-0911GridCenter-11LiverpoolMerseysideUKOvercurrent relay scheme for underground cable protection with IEC curve and backup distance relay.
RS-102-Bdistance1035.2trueovercurrentSiemens7SA5220.03IEEEtransmission linetransmission line0.0370.292013-09-172020-11-02220TransLine-03BerlinBerlinGermanyDistance relay scheme for 220kV transmission line, IEEE curve, backup overcurrent.
RS-103-Cdifferential8.7falseblankABBREF6150.21definite timetransformertransformer0.12blank2012-03-292019-05-1066PowerHub-07AhmedabadGujaratIndiaTransformer differential protection using ABB relay, definite time, no backup protection.
RS-104-Dvoltage120.5falseblankGEMLV-3121.3definite timebusbarbusbar0.15blank2018-08-242022-12-010.4Busbar-02Cape TownWestern CapeSouth AfricaLow voltage busbar protection using GE voltage relay, definite time curve.
RS-105-Efrequency72.1trueovercurrentArevaP3410.22IECgeneratorwind turbine0.090.342021-02-152023-04-170.4WindGen-01AarhusCentral DenmarkDenmarkWind turbine frequency relay protection, IEC curve, backup overcurrent applied.
RS-106-Fdirectional210trueovercurrentSEL751A0.41inversefeederunderground cable0.230.492019-07-122022-06-1622CableFeeder-12Las VegasNevadaUSADirectional relay for cable feeder, inverse curve, backup overcurrent present.
RS-107-Govercurrent180.2falseblankSiemens7SJ850.27IECfeederdistribution cable0.16blank2016-10-192021-03-106.6Feeder-09BangaloreKarnatakaIndiaFeeder protection with Siemens overcurrent relay, IEC curve, no backup.
RS-108-Hdistance2200.5truedifferentialSEL4210.01inversetransmission linetransmission line0.0230.182010-04-042018-09-21500EHVTrans-03UlaanbaatarUlaanbaatarMongoliaSEL distance relay for EHV transmission line, inverse curve, backup differential.

What the 103 rows show

from the 103-row sample

Distance (relay type) stands out: mean setting_pickup_current is 1,754, against 85.9 for the rest.

  • 60%backup_protection_present = true
  • 110.5median setting_pickup_current
  • 5coordination curve types
  • 10zone of protections
  • 11relay manufacturers
  • 13primary element protecteds
Mean setting_pickup_current by relay_type103 rows
01,0002,000211.3over…20 ro…1,754dist…20 ro…7.7diff…20 ro…170.1dire…7 rows19.0volt…19 ro…30.9freq…9 rows115.1other8 rows
setting_pickup_current103 rows, in bands of 500
0459083741312202,0004,000setting_pickup_current →

Median 110.5, from 0.0 to 3,901.

backup_relay_type62 rows with a value · 41 left blank
  1. overcurrent27
  2. distance11
  3. differential11
  4. voltage7
  5. directional6
21 columns by typefrom the column list below
  • string 13
  • float 5
  • date 2
  • boolean 1

Columns

21 columns in four groups
blueprint · 21 columns
columntypedescriptionexample
Text 13 columns
relay_scheme_idstringUnique identifier for each protective relay schemeuniqueRS-101-A
relay_typestringType of protective relay used (e.g., overcurrent, distance, differential)7 valuesovercurrent
relay_manufacturerstringManufacturer of the relay device11 manufacturers · optionalSchneider Electric
relay_modelstringModel number or name of the relay deviceoptionalSEP-3421
coordination_curve_typestringType of coordination curve used (e.g., IEC, IEEE, inverse, definite time)IEC · IEEE · inverse · definite time · other · optionalIEC
zone_of_protectionstringZone or area of the power system protected by this relay scheme (e.g., busbar, feeder, transformer)10 protectionsfeeder
primary_element_protectedstringThe primary system element protected (e.g., transformer, transmission line, generator)distribution cable
backup_relay_typestringType of backup relay (if applicable)5 types · optionaldistance
scheme_descriptionstringDetailed description of the relay scheme and its applicationoptionalOvercurrent relay scheme …
location_substationstringName or identifier of the substation where the relay scheme is installedoptionalGridCenter-11
location_citystringCity where the relay scheme is installedoptionalLiverpool
location_statestringState or province where the relay scheme is installedoptionalMerseyside
location_countrystringCountry where the relay scheme is installedoptionalUK
Numbers 5 columns
setting_pickup_currentfloatPickup current setting for the relay (in Amperes)0 or more · optional158.7
setting_time_delayfloatTime delay setting for the relay (in seconds)0 or more · optional0.31
fault_clearing_timefloatTime taken to clear a fault (in seconds)0 or more · optional0.19
backup_clearing_timefloatBackup relay fault clearing time (in seconds, if applicable)0 or more · optional0.44
system_voltage_levelfloatNominal voltage level of the protected system (in kV)0 or more · optional11
Dates and times 2 columns
date_commissioneddateDate when the relay scheme was commissionedoptional2017-06-12
last_setting_review_datedateDate of the most recent review or update of relay settingsoptional2023-08-09
True or false 1 column
backup_protection_presentbooleanIndicates if backup protection is present for this relay schemetrue

Use it for

  • backup protect…60%62 of 103 rowsmean setting pickup c…211.3over…1.8kdist…7.7diff…170.1dire…

    An energy dashboard

    The backup_protection_present rate, setting_pickup_current by relay_type and a breakdown of backup_relay_type. Excel, Power BI or Tableau.

  • Why do the 20 distance rows have a mean setting_pickup_current of 1,754?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable relay schemes with relay_type, relay_manufacturer and relay_model to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 21 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset103 rows21 columns
Yours1,000 rows21 columnslocation_substation: UK only

blueprint · protective-relay-schemes-and-settings

Behind this dataset

Same schema. As many rows as you need.

These 103 rows came out of a blueprint — 21 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • Relay ID unique per device or function
  • Protection function: overcurrent (50/51), distance (21), differential (87), directional (67)
  • ANSI device numbers for protection functions
  • Relay settings: pickup, time delay, time-current curve
  • Zones of protection: Zone 1 (instantaneous), Zone 2, Zone 3
  • Coordination time interval (CTI): 0.2-0.4 seconds
  • Fault types protected: phase, ground, phase-to-phase
  • Directional elements for loop systems
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
protective-relay-schemes-and-settings

What should your data show?

Preview 20 rows free
No signup. No card.