Dynamic Load Modeling for Voltage Stability Analysis
This dataset provides detailed composite load models for voltage stability analysis in power systems, including breakdowns by motor type, electronic, and resistive components, as well as ZIP coefficients for dynamic load behavior. It enables accurate simulation and assessment of grid stability under varying load conditions, supporting both operational planning and academic research.
Sample rows
preview · 8 of 100 rows · all 15 columns| load_model_idstring | total_load_mwfloat | model_namestring | locationstring | total_load_mvarfloat | motor_induction_fractionfloat | motor_synchronous_fractionfloat | electronic_fractionfloat | resistive_fractionfloat | zip_z_coefffloat | zip_i_coefffloat | zip_p_coefffloat | voltage_setpoint_kvfloat | last_updateddatetime | notesstring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LM001 | 38.74 | Central Substation Model | Central Substation | 12.61 | 0.46 | 0.12 | 0.18 | 0.24 | 0.32 | 0.35 | 0.33 | 12.5 | 2024-04-10T09:28:23 | Model includes moderate electronic loads. |
| LM002 | 22.18 | West Bus Composite | Bus 102 | 8.73 | 0.39 | 0.15 | 0.28 | 0.18 | 0.21 | 0.49 | 0.3 | 13.8 | 2024-05-02T17:15:14 | High current ZIP coefficient observed. |
| LM003 | 45.6 | South Industrial Park | Industrial Park South | 18.22 | 0.54 | 0.2 | 0.17 | 0.09 | 0.4 | 0.22 | 0.38 | 11 | 2024-03-28T13:44:07 | Heavy motor load composition. |
| LM004 | 16.05 | North Retail Cluster | Retail Bus 201 | 5.77 | 0.21 | 0.11 | 0.38 | 0.3 | 0.27 | 0.27 | 0.46 | 12 | 2024-04-15T10:21:36 | Retail area, higher electronic load. |
| LM005 | 10.22 | East Bus Office | Bus 303 | 3.41 | 0.13 | 0.05 | 0.47 | 0.35 | 0.19 | 0.39 | 0.42 | 11.8 | 2024-05-08T15:19:45 | Office district, high constant power. |
| LM006 | 7.85 | Greenfield Residential | Greenfield | 2.64 | 0.32 | 0.08 | 0.22 | 0.38 | 0.34 | 0.28 | 0.38 | 10.5 | 2024-03-18T11:34:27 | Residential area, resistive dominant. |
| LM007 | 26.72 | Metro Transit Hub | Transit Hub | 8.99 | 0.29 | 0.15 | 0.37 | 0.19 | 0.22 | 0.38 | 0.4 | 13.2 | 2024-04-09T08:22:53 | blank |
| LM008 | 33.55 | Airport Zone Model | Airport Substation | 11.41 | 0.41 | 0.12 | 0.34 | 0.13 | 0.25 | 0.53 | 0.22 | 14 | 2024-05-13T12:00:13 | Peak travel period load. |
| LM009 | 19.66 | Tech Park Model | Tech Park 1 | 6.4 | 0.19 | 0.09 | 0.45 | 0.27 | 0.31 | 0.29 | 0.4 | 10.7 | 2024-04-17T16:42:43 | High technology equipment. |
| LM010 | 24.79 | Harbor Facility | Harbor Bus 9 | 8.01 | 0.36 | 0.19 | 0.23 | 0.22 | 0.41 | 0.22 | 0.37 | 12.9 | 2024-03-24T14:08:39 | blank |
| LM011 | 12.4 | River Valley Model | River Valley | 4.28 | 0.26 | 0.07 | 0.14 | 0.53 | 0.29 | 0.34 | 0.37 | 11.3 | 2024-04-20T08:51:16 | Dominant resistive ZIP. |
| LM012 | 17.77 | East Mall Model | Mall East | 6.07 | 0.22 | 0.06 | 0.4 | 0.32 | 0.17 | 0.41 | 0.42 | 12.2 | 2024-03-19T12:03:22 | blank |
| LM013 | 28.01 | University Campus | Campus Grid | 9.32 | 0.31 | 0.18 | 0.22 | 0.29 | 0.32 | 0.24 | 0.44 | 13.6 | 2024-05-15T17:45:51 | Seasonal variation expected. |
| LM014 | 14.49 | Midtown Offices | Midtown Bus 4 | 4.67 | 0.12 | 0.06 | 0.51 | 0.31 | 0.28 | 0.27 | 0.45 | 11.6 | 2024-03-29T13:19:08 | blank |
| LM015 | 34.2 | Northside Hospital Model | Hospital North | 10.96 | 0.24 | 0.16 | 0.48 | 0.12 | 0.18 | 0.37 | 0.45 | 12.7 | 2024-04-03T09:14:37 | Hospital, high electronic equipment. |
| LM016 | 41.58 | Downtown Commercial Model | Downtown Bus 12 | 16.09 | 0.29 | 0.17 | 0.36 | 0.18 | 0.44 | 0.18 | 0.38 | 14.1 | 2024-05-06T18:35:23 | Commercial grid, high load. |
| LM017 | 9.38 | West Residential Model | Westside | 3.52 | 0.3 | 0.09 | 0.26 | 0.35 | 0.25 | 0.36 | 0.39 | 10.4 | 2024-04-13T11:07:10 | Residential, above average induction. |
| LM018 | 15.71 | Suburban Plaza Model | Suburban Plaza | 4.94 | 0.23 | 0.1 | 0.44 | 0.23 | 0.36 | 0.24 | 0.4 | 13 | 2024-03-25T18:49:24 | blank |
| LM019 | 52.17 | Eastside Industrial | Eastside Bus 7 | 20.43 | 0.61 | 0.14 | 0.13 | 0.12 | 0.38 | 0.33 | 0.29 | 15.2 | 2024-04-21T15:40:56 | Heavy industrial, high induction. |
| LM020 | 20.26 | Highland Retail | Highland Center | 7.11 | 0.18 | 0.09 | 0.52 | 0.21 | 0.27 | 0.32 | 0.41 | 11.9 | 2024-04-02T09:53:34 | Retail, highest electronic fraction. |
What the 100 rows show
from the 100-row sample- 33.0median total_
load_ mw - 10.1median total_
load_ mvar - 0.29median motor_
induction_ fraction - 0.13median motor_
synchronous_ fraction - 0.37median electronic_
fraction - 0.17median resistive_
fraction
Median 33.0, from 7.8 to 140.3.
- string 4
- float 10
- datetime 1
Columns
15 columns in three groups| column | type | description | example |
|---|---|---|---|
| Text 4 columns | |||
load_model_id | string | Unique identifier for each composite load modelunique | LM001 |
model_name | string | Descriptive name for the load model | Central Substation Model |
location | string | Physical or logical location of the load model (e.g., substation name, bus number)optional | Central Substation |
notes | string | Additional notes or comments about the load modeloptional | Peak travel period load. |
| Numbers 10 columns | |||
total_load_mw | float | Total load represented by the model in megawatts (MW)0 or more | 38.74 |
total_load_mvar | float | Total reactive load represented by the model in megavolt-amperes reactive (MVAr)0 or more | 12.61 |
motor_induction_fraction | float | Fraction of total load attributed to induction motors (0-1)0 to 1 | 0.46 |
motor_synchronous_fraction | float | Fraction of total load attributed to synchronous motors (0-1)0 to 1 | 0.12 |
electronic_fraction | float | Fraction of total load attributed to electronic (constant power) components (0-1)0 to 1 | 0.18 |
resistive_fraction | float | Fraction of total load attributed to resistive components (0-1)0 to 1 | 0.24 |
zip_z_coeff | float | ZIP model coefficient for constant impedance (Z) portion0 to 1 | 0.32 |
zip_i_coeff | float | ZIP model coefficient for constant current (I) portion0 to 1 | 0.35 |
zip_p_coeff | float | ZIP model coefficient for constant power (P) portion0 to 1 | 0.33 |
voltage_setpoint_kv | float | Nominal voltage setpoint for the load model in kilovolts (kV)0 or more · optional | 12.5 |
| Dates and times 1 column | |||
last_updated | datetime | Timestamp of the last update to this load model record | 2024-04-10T09:28:23 |
Use it for
An energy dashboard
Total_
load_ mw. Excel, Power BI or Tableau. What pattern can you find in 100 rows?
A class exercise
Hand out the rows and one question. Everyone works from the same 100 rows.
- Load models100LM00138.74LM00222.18LM00345.6
A software demo
Believable load models with model_
name, location and total_ load_ mw to fill a screen in front of a buyer.
blueprint · dynamic-load-modeling-for-voltage-stability-analysis
Behind this dataset
Same schema. As many rows as you need.
These 100 rows came out of a blueprint — 15 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- Bus ID or substation node for load location
- ZIP model coefficients: %Z (impedance), %I (current), %P (power)
- Motor load percentage: typically 40-60% of total load
- Electronic load (constant power): computers, LED lighting
- Voltage dependency: load varies with V^2 for Z, V for I, constant for P
- Dynamic load recovery time constants (seconds)
- OLTC (on-load tap changer) and capacitor bank interaction
- Voltage collapse margin analysis and critical voltage thresholds
1 credit per row. Preview 20 rows free. Buy rows for the full run.
- Exports
- CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
- Licence
- yours to use, including commercially
- API slug
- dynamic-load-modeling-for-voltage-stability-analysis