Power Transformers and Autotransformers
This dataset provides detailed technical and operational specifications for power transformers and autotransformers, including electrical ratings, impedance, tap changer settings, winding configurations, and cooling methods. It is designed for asset management, grid modeling, and operational optimization in electric power systems, supporting both engineering analysis and maintenance planning.
Sample rows
preview · 8 of 100 rows · all 18 columns| transformer_idstring | cooling_typestring | mva_ratingfloat | manufacturerstring | transformer_typestring | primary_voltage_kvfloat | secondary_voltage_kvfloat | impedance_percentfloat | tap_ratio_minfloat | tap_ratio_maxfloat | tap_step_percentfloat | number_of_tap_positionsinteger | load_tap_changer_presentboolean | winding_configurationstring | installation_locationstring | year_of_manufactureinteger | serial_numberstring | in_serviceboolean |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX-001-PTA | ONAN | 50 | ABB | Power Transformer | 220 | 110 | 10.4 | 0.95 | 1.05 | 1.25 | 17 | true | Delta-Wye | Central Substation | 2014 | ABB-PT-2014-00945 | true |
| TX-002-ATB | ONAF | 80.5 | Siemens | Autotransformer | 400 | 220 | 7.8 | 0.98 | 1.06 | 1.5 | 15 | true | Wye-Wye | South Grid Hub | 2018 | SIE-AT-18-2578 | true |
| TX-003-PTC | OFAF | 25.2 | GE | Power Transformer | 110 | 33 | 8.3 | 0.97 | 1.03 | 1 | 9 | true | Delta-Delta | East Transmission Site | 2012 | GE-PT-12-0427 | true |
| TX-004-PTD | ONAN | 16 | Hitachi | Power Transformer | 33 | 11 | 5.5 | 0.99 | 1.01 | 0.5 | 5 | true | Wye-Delta | North Distribution | 2019 | HIT-PT-19-2345 | true |
| TX-005-PTA | OFWF | 100 | Hyundai | Power Transformer | 500 | 230 | 9.2 | 0.94 | 1.06 | 1.2 | 13 | true | Wye-Wye | West Main Substation | 2007 | HYU-PT-07-8173 | true |
| TX-006-PTB | ONAF | 40.5 | Toshiba | Power Transformer | 66 | 11 | 6.8 | 0.98 | 1.04 | 1 | 7 | true | Delta-Wye | Metro Distribution | 2015 | TOS-PT-15-3342 | true |
| TX-007-ATC | ONAF | 60 | Alstom | Autotransformer | 220 | 132 | 5.2 | 0.96 | 1.03 | 0.75 | 11 | true | Wye-Wye | Grid Junction A | 2020 | ALS-AT-20-6543 | true |
| TX-008-PTD | ONAN | 12.5 | Siemens | Power Transformer | 33 | 6.6 | 7 | 0.99 | 1.01 | 0.5 | 3 | true | Delta-Delta | Rural East | 2016 | SIE-PT-16-0998 | true |
| TX-009-PTA | OFAF | 125 | GE | Power Transformer | 500 | 230 | 8.7 | 0.93 | 1.05 | 1.4 | 12 | true | Delta-Wye | West Regional Hub | 2011 | GE-PT-11-3071 | true |
| TX-010-PTB | ONAN | 10.2 | Hitachi | Power Transformer | 33 | 6.6 | 6.5 | 0.98 | 1.02 | 0.5 | 5 | true | Wye-Delta | Village Center | 2017 | HIT-PT-17-7812 | true |
| TX-011-ATD | ONAF | 70 | ABB | Autotransformer | 330 | 220 | 13.2 | 0.95 | 1.07 | 2 | 13 | true | Wye-Wye | Central Station | 2015 | ABB-AT-15-3322 | true |
| TX-012-PTC | ONAN | 20 | Toshiba | Power Transformer | 66 | 11 | 6.3 | 0.97 | 1.03 | 1 | 7 | true | Delta-Wye | City East Substation | 2013 | TOS-PT-13-1282 | true |
| TX-013-PTD | ONAN | 6.3 | GE | Power Transformer | 33 | 6.6 | 5.9 | 0.99 | 1.01 | 0.5 | 3 | true | Delta-Delta | Remote Substation | 2016 | GE-PT-16-4398 | true |
| TX-014-PTA | ONAF | 55 | Hyundai | Power Transformer | 220 | 110 | 10.1 | 0.95 | 1.05 | 1.2 | 13 | true | Delta-Wye | Urban Center | 2009 | HYU-PT-09-1609 | true |
| TX-015-PTB | OFAF | 18.5 | Hitachi | Power Transformer | 66 | 11 | 6 | 0.97 | 1.03 | 1 | 7 | true | Wye-Delta | Industrial Park | 2014 | HIT-PT-14-2382 | true |
| TX-016-PTC | ONAN | 35 | ABB | Power Transformer | 110 | 33 | 8.1 | 0.96 | 1.04 | 1 | 9 | true | Delta-Wye | Suburban Substation | 2010 | ABB-PT-10-1092 | true |
| TX-017-PTD | ONAN | 13.7 | GE | Power Transformer | 33 | 6.6 | 7.5 | 0.99 | 1.01 | 0.5 | 5 | true | Delta-Delta | Rural West | 2018 | GE-PT-18-5987 | true |
| TX-018-PTA | ONAF | 45 | Hyundai | Power Transformer | 220 | 110 | 10 | 0.95 | 1.05 | 1.25 | 17 | true | Delta-Wye | Downtown Grid | 2005 | HYU-PT-05-6283 | true |
| TX-019-PTB | OFAF | 20 | Toshiba | Power Transformer | 66 | 11 | 6.3 | 0.97 | 1.03 | 1 | 7 | true | Delta-Wye | City West Substation | 2012 | TOS-PT-12-2382 | true |
| TX-020-ATC | OFWF | 120 | Siemens | Autotransformer | 400 | 220 | 7.9 | 0.97 | 1.06 | 1.4 | 12 | true | Wye-Wye | Interstate Junction | 2017 | SIE-AT-17-7432 | true |
What the 100 rows show
from the 100-row sampleOFWF (cooling type) stands out: mean mva_
- 39.0median mva_
rating - 2transformer types
- 4winding configurations
- 110.0median primary_
voltage_ kv - 13.8median secondary_
voltage_ kv - 7.5median impedance_
percent
Median 39.0, from 6.3 to 300.0.
- string 7
- integer 2
- float 7
- boolean 2
Columns
18 columns in three groups| column | type | description | example |
|---|---|---|---|
| Text 7 columns | |||
transformer_id | string | Unique identifier for each transformer or autotransformer unitunique | TX-001-PTA |
transformer_type | string | Type of transformer (e.g., Power Transformer, Autotransformer)Power Transformer · Autotransformer | Power Transformer |
winding_configuration | string | Winding configuration (e.g., Delta-Wye, Wye-Wye, Delta-Delta)Delta-Wye · Wye-Wye · Delta-Delta · Wye-Delta · Other | Delta-Wye |
cooling_type | string | Cooling method used (e.g., ONAN, ONAF, OFAF, OFWF)ONAN · ONAF · OFAF · OFWF · Other | ONAN |
installation_location | string | Physical location or substation where the transformer is installedoptional | Central Substation |
manufacturer | string | Name of the transformer manufactureroptional | ABB |
serial_number | string | Manufacturer's serial number for the transformeroptional | ABB-PT-2014-00945 |
| Numbers 9 columns | |||
mva_rating | float | Apparent power rating of the transformer in MVA0.1 or more | 50 |
primary_voltage_kv | float | Rated primary winding voltage in kilovolts (kV)0.1 or more | 220 |
secondary_voltage_kv | float | Rated secondary winding voltage in kilovolts (kV)0.1 or more | 110 |
impedance_percent | float | Transformer impedance expressed as a percentage0.01 to 100 | 10.4 |
tap_ratio_min | float | Minimum tap ratio available for voltage adjustment0.5 or more | 0.95 |
tap_ratio_max | float | Maximum tap ratio available for voltage adjustment0.5 or more | 1.05 |
tap_step_percent | float | Percentage change per tap step0.01 to 10 | 1.25 |
number_of_tap_positions | integer | Total number of tap positions available1 or more | 17 |
year_of_manufacture | integer | Year the transformer was manufactured1,900 to 2,100 · optional | 2014 |
| True or false 2 columns | |||
load_tap_changer_present | boolean | Indicates if a load tap changer is installed | true |
in_service | boolean | Indicates whether the transformer is currently in service | true |
Use it for
An energy dashboard
Mva_
rating by cooling_ type and a breakdown of manufacturer. Excel, Power BI or Tableau. Why do the 14 OFWF rows have a mean mva_
rating of 191.4? A root-cause class exercise
Hand out the rows and one question. The answer is in the data, not in the brief.
- Transformers100TX-001-PTA50ONANTX-002-ATB80.5ONAFTX-003-PTC25.2OFAF
A software demo
Believable transformers with transformer_
type, mva_ rating and primary_ voltage_ kv to fill a screen in front of a buyer.
blueprint · power-transformers-and-autotransformers
Behind this dataset
Same schema. As many rows as you need.
These 100 rows came out of a blueprint — 18 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- Transformer ID unique per unit
- MVA rating: base, forced air (FOA), forced oil (FOW)
- Voltage ratio: primary/secondary (e.g., 230/115 kV)
- Winding connection: wye, delta, zigzag
- Impedance on transformer base (% or per unit)
- Tap changer type: no-load (NLTC), on-load (OLTC/LTC)
- Tap range: typically ±10% in 32 steps (5/8% per step)
- Load tap changer (LTC) control mode: manual, automatic, voltage control
1 credit per row. Preview 20 rows free. Buy rows for the full run.
- Exports
- CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
- Licence
- yours to use, including commercially
- API slug
- power-transformers-and-autotransformers