• Energy
  • 15 columns
  • 501 rows
  • 8 formats

FACTS Devices and Voltage Control Equipment

This dataset provides detailed, structured information on Flexible AC Transmission System (FACTS) devices and voltage control equipment deployed across power grids, including device types, capacities, operational status, and installation locations. It supports asset management, grid reliability analysis, and optimization of dynamic voltage support and power flow control.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Asset management and lifecycle tracking of FACTS devices

Sample rows

preview · 8 of 501 rows · all 15 columns
device_idstringstatusstringmin_operating_current_afloatmanufacturerstringdevice_typestringdevice_namestringlocation_substationstringlocation_regionstringvoltage_level_kvfloatrated_capacity_mvarfloatcommissioning_datedatecontrol_modestringconnected_line_idstringmax_operating_current_afloatremarksstring
SVC_0001_NGActive24.2ABBSVCNorthern Grid Voltage SVCNorthville SVCNorthern Grid220802020-07-15Voltage ControlNG-220-001320.5Supports voltage stability for regional grid peaks.
STATCOM_002_SHActive12.4HitachiSTATCOMSouthern Hub STATCOM ASouthpoint STATCOMSouthern Hub132602019-11-23Voltage ControlSH-132-002215.7Operational since 2019, provides dynamic voltage support.
TCSC_03_WBActive77.5GE Grid SolutionsTCSCWestern Belt TCSC MainWestside Comp StationWestern Belt4001252021-05-04Power Flow ControlWB-400-003480.9Controls power flow for high capacity corridor.
SERCOMP_004_CGActive150.1SchneiderSeries CompensationCentral Grid Series CompCentral SVCCentral Grid7652502022-03-28Power Flow ControlCG-765-0041050.2Critical for urban load balancing, commissioned 2022.
SVC_005_MZActive200ToshibaSVCMountain Zone SVC-5Montview SVCMountain Zone12005002023-10-09Reactive Power CompensationMZ-1200-0051850High-capacity SVC for mountainous transmission.
STATCOM_006_EFActive2.5SiemensSTATCOMEastern Fringe STATCOMEastwood STATCOMEastern Fringe66102016-01-13Voltage ControlEF-66-00650.2Supports fringe area voltage with rapid response.
TCSC_007_PCActive25.6MitsubishiTCSCPacific Coast TCSCPacifica TCSCPacific Coast245902018-09-21Power Flow ControlPC-245-007310.8Enables flexible control for coastal transmission.
SERCOMP_008_HCDecommissioned0.2blankSeries CompensationHeritage Corridor Series CompHeritage SVCHeritage Corridor3332004-11-17Power Flow Controlblank9.1Historic device, replaced in 2018 with modern equipment.

What the 501 rows show

from the 501-row sample

Active status stands out: mean min_operating_current_a is 92.6, against 6.0 for the rest.

  • 44.1median min_operating_current_a
  • 3control modes
  • 4device types
  • 15location regions
  • 245median voltage_level_kv
  • 100median rated_capacity_mvar
Mean min_operating_current_a by status501 rows
05010092.6Active331 rows2.8Inactive94 rows63.3Under Ma…11 rows0.98Decommis…65 rows
min_operating_current_a501 rows, in bands of 25
010020019174524641282423220125225min_operating_current_a →

Median 44.1, from 0.0 to 200.1.

manufacturer426 rows with a value · 75 left blank
  1. Schneider88
  2. GE Grid Solutions79
  3. Hitachi59
  4. ABB56
  5. Mitsubishi50
  6. Siemens49
  7. Toshiba45
15 columns by typefrom the column list below
  • string 10
  • float 4
  • date 1

Columns

15 columns in three groups
blueprint · 15 columns
columntypedescriptionexample
Text 10 columns
device_idstringUnique identifier for each FACTS device or voltage control equipmentuniqueSVC_0001_NG
device_typestringType of FACTS device (e.g., SVC, STATCOM, TCSC, Series Compensation)SVC · STATCOM · TCSC · Series CompensationSVC
device_namestringDescriptive name or label of the deviceSouthern Hub STATCOM A
location_substationstringName of the substation where the device is installedNorthville SVC
location_regionstringGeographical region or grid zone of installationNorthern Grid
manufacturerstringName of the manufacturer or supplier of the device7 manufacturers · optionalABB
statusstringOperational status of the deviceActive · Inactive · Under Maintenance · DecommissionedActive
control_modestringPrimary control mode (e.g., Voltage Control, Power Flow Control, Reactive Power Compensation)3 valuesVoltage Control
connected_line_idstringIdentifier of the transmission line or bus to which the device is connectedoptionalNG-220-001
remarksstringAdditional notes or remarks about the deviceoptionalSupports voltage stabilit…
Numbers 4 columns
voltage_level_kvfloatNominal voltage level in kilovolts (kV) at which the device operates1 to 1,200220
rated_capacity_mvarfloatReactive power rating of the device in Mega Volt-Amperes Reactive (MVAr)1 or more80
max_operating_current_afloatMaximum operating current in amperes (A)0 or more · optional320.5
min_operating_current_afloatMinimum operating current in amperes (A)0 or more · optional24.2
Dates and times 1 column
commissioning_datedateDate when the device was commissioned and became operational2020-07-15

Use it for

  • median min ope…44.1501 rowsmean min operating cu…92.6Acti…2.8Inac…63.3Unde…0.98Deco…

    An energy dashboard

    Min_operating_current_a by status and a breakdown of manufacturer. Excel, Power BI or Tableau.

  • Why do the 331 Active rows have a mean min_operating_current_a of 92.6?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable devices with device_type, device_name and location_substation to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 15 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset501 rows15 columns
Yours1,000 rows15 columnslocation_substation: UK only

blueprint · facts-devices-and-voltage-control-equipment

Behind this dataset

Same schema. As many rows as you need.

These 501 rows came out of a blueprint — 15 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • FACTS device ID unique
  • Device type: SVC (Static VAR Compensator), STATCOM, TCSC, SSSC, UPFC
  • Rating: MVAR for SVC/STATCOM, % compensation for series devices
  • Control mode: voltage control, VAR control, power flow control
  • Response time: typically < 1 cycle for STATCOM
  • Operating range: capacitive and inductive MVAR
  • Voltage setpoint and droop characteristics
  • Harmonic filtering requirements
Rows
Open the blueprint in Data Factory

1 credit per row. New accounts start with 25 free credits.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
facts-devices-and-voltage-control-equipment

What should your data show?

Preview 20 rows free
No signup. No card.