Capacitor Banks and Reactive Compensation
This dataset provides comprehensive asset-level details for shunt capacitor and reactor banks used in reactive power management, including MVAR ratings, voltage levels, control types, and harmonic filtering features. It supports grid optimization, asset tracking, and compliance analysis for electric utilities and power system operators.
Sample rows
preview · 8 of 100 rows · all 19 columns| bank_idstring | statusstring | mvar_ratingfloat | voltage_regulation_enabledboolean | location_statestring | bank_typestring | location_namestring | location_street_addressstring | location_citystring | location_postal_codestring | location_countrystring | voltage_level_kvfloat | switching_control_typestring | power_factor_correction_enabledboolean | harmonic_filtering_enabledboolean | harmonic_filter_typestring | installation_datedate | last_maintenance_datedate | notesstring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CBK001 | active | 12.5 | true | TX | capacitor | Central Substation | 110 Main St | Houston | 77002 | USA | 13.8 | automatic | true | false | none | 2016-03-15 | 2023-05-21 | Annual inspection completed. |
| RCT456 | active | 8.1 | false | TX | reactor | West Feeder | 4027 Westview Ave | Dallas | 75219 | USA | 33 | manual | false | false | none | 2012-11-06 | 2021-09-10 | Manual switching only. |
| CBK002 | maintenance | 5.6 | true | IL | capacitor | North Substation | 89 North Rd | Chicago | 60614 | USA | 11 | time-based | true | true | passive | 2018-07-22 | 2022-12-12 | Passive filter replaced last year. |
| RCT789 | active | 3.2 | false | CA | reactor | East Feeder | 31 East Ln | San Diego | 92121 | USA | 6.6 | remote | false | true | active | 2015-02-01 | 2023-01-19 | Active filter added in 2020. |
| CBK003 | active | 15.2 | true | TN | capacitor | River Substation | 17 Riverside Dr | Memphis | 38103 | USA | 24 | automatic | true | true | hybrid | 2019-09-12 | 2023-11-02 | Hybrid filter system. |
| RCT010 | inactive | 2.6 | false | AZ | reactor | South Feeder | 222 Cypress Rd | Phoenix | 85003 | USA | 4.16 | manual | false | false | none | 2010-05-09 | 2020-08-10 | Currently out of service. |
| CBK004 | active | 10.8 | true | FL | capacitor | Lakeview Substation | 154 Lakeview Blvd | Orlando | 32801 | USA | 13.8 | voltage-based | true | false | none | 2017-04-03 | 2022-04-22 | Scheduled for upgrade. |
| RCT011 | maintenance | 9.5 | false | MI | reactor | Industrial Feeder | 5300 Industrial Pkwy | Detroit | 48226 | USA | 33 | remote | false | true | active | 2013-10-28 | 2022-07-17 | Filter malfunction reported. |
| CBK005 | active | 7.3 | true | GA | capacitor | City Center Substation | 200 City Center | Atlanta | 30303 | USA | 11 | automatic | true | true | passive | 2020-01-18 | 2023-09-30 | Passive filter tuned for 3rd harmonics. |
| RCT012 | decommissioned | 4.7 | false | NC | reactor | Midtown Feeder | 44 Midtown St | Charlotte | 28202 | USA | 13.8 | manual | false | false | none | 2011-08-24 | 2020-02-15 | Unit decommissioned in 2021. |
| CBK006 | active | 13.9 | true | CA | capacitor | Park Substation | 800 Park Ave | San Francisco | 94107 | USA | 24 | voltage-based | true | true | hybrid | 2018-05-11 | 2022-03-14 | Hybrid filter upgraded in 2022. |
| RCT013 | active | 6.3 | false | WA | reactor | Downtown Feeder | 1201 Downtown Blvd | Seattle | 98101 | USA | 13.8 | automatic | false | false | none | 2014-09-26 | 2021-07-08 | No harmonic filter installed. |
| CBK007 | active | 9.2 | true | MA | capacitor | Metro Substation | 205 Metro St | Boston | 02114 | USA | 13.8 | automatic | true | false | none | 2016-12-05 | 2023-07-17 | System running optimally. |
| RCT014 | active | 7.7 | false | FL | reactor | Bay Feeder | 310 Bayfront Dr | Tampa | 33602 | USA | 24 | manual | false | true | passive | 2017-03-11 | 2022-08-09 | Passive filter installed. |
| CBK008 | active | 11.1 | true | CA | capacitor | Harbor Substation | 900 Harbor Dr | San Pedro | 90731 | USA | 13.8 | automatic | true | true | active | 2019-12-18 | 2023-06-15 | Active filter added recently. |
| RCT015 | inactive | 4.2 | false | CO | reactor | Highland Feeder | 540 Highland Rd | Denver | 80211 | USA | 6.6 | manual | false | false | none | 2012-04-13 | 2021-02-20 | Not scheduled for upgrade. |
| CBK009 | active | 16.7 | true | UT | capacitor | Airport Substation | 3700 Airport Rd | Salt Lake City | 84122 | USA | 24 | automatic | true | true | hybrid | 2021-02-28 | 2023-08-11 | Hybrid system installed post commissioning. |
| RCT016 | maintenance | 5.9 | false | NV | reactor | Valley Feeder | 220 Valley Rd | Las Vegas | 89101 | USA | 13.8 | remote | false | true | active | 2016-07-19 | 2022-09-27 | Active filter scheduled for replacement. |
| CBK010 | active | 14.6 | true | CO | capacitor | Mountain Substation | 899 Mountain Ave | Boulder | 80302 | USA | 24 | automatic | true | false | none | 2017-11-13 | 2022-10-05 | No filters installed. |
| RCT017 | decommissioned | 3.5 | false | OR | reactor | Greenway Feeder | 60 Greenway Blvd | Portland | 97201 | USA | 6.6 | manual | false | false | none | 2010-10-08 | 2018-03-12 | Unit retired. |
What the 100 rows show
from the 100-row sampleActive status stands out: 49 of its 71 rows have voltage_
- 50%voltage_
regulation_ enabled = true - 7.7median mvar_
rating - 2bank types
- 4location countries
- 5harmonic filter types
- 6switching control types
Active status's mean mvar_
Median 7.7, from 1.4 to 24.9.
- string 12
- float 2
- date 2
- boolean 3
Columns
19 columns in four groups| column | type | description | example |
|---|---|---|---|
| Text 12 columns | |||
bank_id | string | Unique identifier for the capacitor or reactor bankunique | CBK001 |
bank_type | string | Type of bank: 'capacitor' or 'reactor'capacitor · reactor | capacitor |
location_name | string | Name or description of the bank's location (substation, feeder, etc.) | Central Substation |
location_street_address | string | Street address of the bank locationoptional | 110 Main St |
location_city | string | City of the bank locationoptional | Houston |
location_state | string | State or province of the bank locationoptional | TX |
location_postal_code | string | Postal code of the bank locationoptional | 77002 |
location_country | string | Country of the bank location4 countries · optional | USA |
switching_control_type | string | Type of switching control used (manual, automatic, remote, etc.)6 values | automatic |
harmonic_filter_type | string | Type of harmonic filter used (if any)none · passive · active · hybrid · other · optional | none |
status | string | Operational status of the bank (active, inactive, maintenance, decommissioned)active · inactive · maintenance · decommissioned | active |
notes | string | Additional notes or comments about the bankoptional | Manual switching only. |
| Numbers 2 columns | |||
mvar_rating | float | Reactive power rating of the bank in MVAR0.1 or more | 12.5 |
voltage_level_kv | float | Nominal voltage level at which the bank operates (in kV)0.1 or more | 13.8 |
| Dates and times 2 columns | |||
installation_date | date | Date when the bank was installedoptional | 2016-03-15 |
last_maintenance_date | date | Date of last maintenance performed on the bankoptional | 2023-05-21 |
| True or false 3 columns | |||
voltage_regulation_enabled | boolean | Indicates if voltage regulation is enabled for this bank | true |
power_factor_correction_enabled | boolean | Indicates if power factor correction is enabled for this bank | true |
harmonic_filtering_enabled | boolean | Indicates if harmonic filtering is enabled for this bank | false |
Use it for
An energy dashboard
The voltage_
regulation_ enabled rate, mvar_ rating by status and a breakdown of location_ state. Excel, Power BI or Tableau. Why do 50 of 100 rows have voltage_
regulation_ enabled = true? A root-cause class exercise
Hand out the rows and one question. The answer is in the data, not in the brief.
- Banks100CBK00112.5activeRCT4568.1activeCBK0025.6maintena…
A software demo
Believable banks with bank_
type, location_ name and location_ street_ address to fill a screen in front of a buyer.
blueprint · capacitor-banks-and-reactive-compensation
Behind this dataset
Same schema. As many rows as you need.
These 100 rows came out of a blueprint — 19 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- Bank ID unique per installation
- Reactive power rating (MVAR) at nominal voltage
- Voltage level and connection (wye, delta)
- Switching control: fixed, switched manually, automatic (voltage, VAR, time)
- Number of steps for multi-step banks
- Capacitor units per phase
- Tuning for harmonic filtering (if applicable)
- Inrush current limiting reactors
1 credit per row. Preview 20 rows free. Buy rows for the full run.
- Exports
- CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
- Licence
- yours to use, including commercially
- API slug