Capacitor Banks and Reactive Compensation

This dataset provides comprehensive asset-level details for shunt capacitor and reactor banks used in reactive power management, including MVAR ratings, voltage levels, control types, and harmonic filtering features. It supports grid optimization, asset tracking, and compliance analysis for electric utilities and power system operators.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Asset management and maintenance scheduling for grid equipment

Sample rows

preview · 8 of 100 rows · all 19 columns
bank_idstringstatusstringmvar_ratingfloatvoltage_regulation_enabledbooleanlocation_statestringbank_typestringlocation_namestringlocation_street_addressstringlocation_citystringlocation_postal_codestringlocation_countrystringvoltage_level_kvfloatswitching_control_typestringpower_factor_correction_enabledbooleanharmonic_filtering_enabledbooleanharmonic_filter_typestringinstallation_datedatelast_maintenance_datedatenotesstring
CBK001active12.5trueTXcapacitorCentral Substation110 Main StHouston77002USA13.8automatictruefalsenone2016-03-152023-05-21Annual inspection completed.
RCT456active8.1falseTXreactorWest Feeder4027 Westview AveDallas75219USA33manualfalsefalsenone2012-11-062021-09-10Manual switching only.
CBK002maintenance5.6trueILcapacitorNorth Substation89 North RdChicago60614USA11time-basedtruetruepassive2018-07-222022-12-12Passive filter replaced last year.
RCT789active3.2falseCAreactorEast Feeder31 East LnSan Diego92121USA6.6remotefalsetrueactive2015-02-012023-01-19Active filter added in 2020.
CBK003active15.2trueTNcapacitorRiver Substation17 Riverside DrMemphis38103USA24automatictruetruehybrid2019-09-122023-11-02Hybrid filter system.
RCT010inactive2.6falseAZreactorSouth Feeder222 Cypress RdPhoenix85003USA4.16manualfalsefalsenone2010-05-092020-08-10Currently out of service.
CBK004active10.8trueFLcapacitorLakeview Substation154 Lakeview BlvdOrlando32801USA13.8voltage-basedtruefalsenone2017-04-032022-04-22Scheduled for upgrade.
RCT011maintenance9.5falseMIreactorIndustrial Feeder5300 Industrial PkwyDetroit48226USA33remotefalsetrueactive2013-10-282022-07-17Filter malfunction reported.

What the 100 rows show

from the 100-row sample

Active status stands out: 49 of its 71 rows have voltage_regulation_enabled = true, against 1 of 29 for the rest.

  • 50%voltage_regulation_enabled = true
  • 7.7median mvar_rating
  • 2bank types
  • 4location countries
  • 5harmonic filter types
  • 6switching control types
Voltage regulation enabled rate by statusvoltage_regulation_enabled = true
0%50%100%69%active49 of 710%inactive0 of 129%maintena…1 of 110%decommis…0 of 6

Active status's mean mvar_rating is 9.8, against 6.4 for inactive, 5.2 for maintenance and 4.6 for decommissioned.

mvar_rating100 rows, in bands of 2.5
0153061824201294412012.525mvar_rating →

Median 7.7, from 1.4 to 24.9.

location_state100 rows · top 10 of 38 values
  1. OH8
  2. TX7
  3. CA7
  4. FL7
  5. TN5
  6. MO5
  7. NC4
  8. CO4
  9. NV3
  10. OR3
19 columns by typefrom the column list below
  • string 12
  • float 2
  • date 2
  • boolean 3

Columns

19 columns in four groups
blueprint · 19 columns
columntypedescriptionexample
Text 12 columns
bank_idstringUnique identifier for the capacitor or reactor bankuniqueCBK001
bank_typestringType of bank: 'capacitor' or 'reactor'capacitor · reactorcapacitor
location_namestringName or description of the bank's location (substation, feeder, etc.)Central Substation
location_street_addressstringStreet address of the bank locationoptional110 Main St
location_citystringCity of the bank locationoptionalHouston
location_statestringState or province of the bank locationoptionalTX
location_postal_codestringPostal code of the bank locationoptional77002
location_countrystringCountry of the bank location4 countries · optionalUSA
switching_control_typestringType of switching control used (manual, automatic, remote, etc.)6 valuesautomatic
harmonic_filter_typestringType of harmonic filter used (if any)none · passive · active · hybrid · other · optionalnone
statusstringOperational status of the bank (active, inactive, maintenance, decommissioned)active · inactive · maintenance · decommissionedactive
notesstringAdditional notes or comments about the bankoptionalManual switching only.
Numbers 2 columns
mvar_ratingfloatReactive power rating of the bank in MVAR0.1 or more12.5
voltage_level_kvfloatNominal voltage level at which the bank operates (in kV)0.1 or more13.8
Dates and times 2 columns
installation_datedateDate when the bank was installedoptional2016-03-15
last_maintenance_datedateDate of last maintenance performed on the bankoptional2023-05-21
True or false 3 columns
voltage_regulation_enabledbooleanIndicates if voltage regulation is enabled for this banktrue
power_factor_correction_enabledbooleanIndicates if power factor correction is enabled for this banktrue
harmonic_filtering_enabledbooleanIndicates if harmonic filtering is enabled for this bankfalse

Use it for

  • voltage regula…50%50 of 100 rowsmean mvar rating by s…9.8acti…6.4inac…5.2main…4.6deco…

    An energy dashboard

    The voltage_regulation_enabled rate, mvar_rating by status and a breakdown of location_state. Excel, Power BI or Tableau.

  • Why do 50 of 100 rows have voltage_regulation_enabled = true?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable banks with bank_type, location_name and location_street_address to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 19 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset100 rows19 columns
Yours1,000 rows19 columnslocation_name: UK only

blueprint · capacitor-banks-and-reactive-compensation

Behind this dataset

Same schema. As many rows as you need.

These 100 rows came out of a blueprint — 19 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • Bank ID unique per installation
  • Reactive power rating (MVAR) at nominal voltage
  • Voltage level and connection (wye, delta)
  • Switching control: fixed, switched manually, automatic (voltage, VAR, time)
  • Number of steps for multi-step banks
  • Capacitor units per phase
  • Tuning for harmonic filtering (if applicable)
  • Inrush current limiting reactors
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
capacitor-banks-and-reactive-compensation

What should your data show?

Preview 20 rows free
No signup. No card.