Gas Insulated Switchgear (GIS) Inspection and SF6 Leak Detection
This dataset provides comprehensive records of gas insulated switchgear inspections, capturing SF6 leak detection, pressure monitoring, partial discharge sensor readings, compartment moisture, and contact alignment verification. It enables detailed tracking of equipment health, supports predictive maintenance, and ensures regulatory compliance for high-voltage electrical infrastructure.
Sample rows
preview · 8 of 400 rows · all 15 columns| inspection_idstring | contact_alignment_statusstring | sf6_pressure_barfloat | action_requiredboolean | switchgear_idstring | inspection_datedate | inspector_namestring | location_sitestring | compartment_idstring | sf6_leak_ppmfloat | partial_discharge_acoustic_dbfloat | partial_discharge_uhf_dbfloat | compartment_moisture_ppmfloat | next_maintenance_datedate | remarksstring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| INSP-00001 | Aligned | 6.84 | false | SG-123A | 2023-01-14 | Victor Pearson | Dallas-NorthHub | CPT-A1 | 0 | 15.3 | 13.7 | 56.2 | 2024-01-15 | Routine inspection completed. No issues found. |
| INSP-00002 | Aligned | 7.1 | false | SG-124B | 2023-01-18 | Priya Shah | Houston-WestSub | CPT-B2 | 0.4 | 19.8 | 17.2 | 38.1 | 2023-11-18 | Routine inspection completed. No issues found. |
| INSP-00003 | Aligned | 7.35 | false | SG-125C | 2023-02-11 | Ethan Lee | Austin-EastGrid | CPT-C1 | 0 | 11.5 | 11.9 | 65.4 | 2024-02-13 | Routine inspection completed. No issues found. |
| INSP-00004 | Aligned | 6.15 | false | SG-126D | 2023-03-21 | Maria Sanchez | SanAntonio-Central | CPT-D3 | 2 | 22.1 | 14.7 | 110.7 | 2023-09-21 | Slight increase in moisture/PD. Recommend closer monitoring. |
| INSP-00005 | Aligned | 7.36 | false | SG-127E | 2023-04-03 | James Howard | ElPaso-Substation3 | CPT-E2 | 1.3 | 18.7 | 16.3 | 90.4 | 2024-04-07 | Routine inspection completed. No issues found. |
| INSP-00006 | Aligned | 6.91 | false | SG-128F | 2023-05-12 | Linda Tran | Amarillo-EastYard | CPT-F1 | 0.8 | 14.6 | 12.5 | 43 | 2024-05-13 | Routine inspection completed. No issues found. |
| INSP-00007 | Aligned | 7.5 | false | SG-129G | 2023-05-28 | Olga Petrov | Lubbock-WestField | CPT-G4 | 0 | 11.2 | 10.4 | 29.8 | 2024-05-28 | Routine inspection completed. No issues found. |
| INSP-00008 | Aligned | 6.5 | false | SG-123A | 2023-06-04 | Ravi Kumar | Dallas-NorthHub | CPT-A2 | 0.7 | 17.9 | 15.6 | 77.2 | 2024-06-04 | Routine inspection completed. No issues found. |
| INSP-00009 | Aligned | 7.2 | false | SG-124B | 2023-06-19 | Sara Martinez | Houston-WestSub | CPT-B1 | 0.5 | 20.5 | 18.8 | 61.9 | 2024-06-21 | Routine inspection completed. No issues found. |
| INSP-00010 | Aligned | 6.96 | false | SG-125C | 2023-07-13 | Elijah Brooks | Austin-EastGrid | CPT-C3 | 1.5 | 24.1 | 19.2 | 95 | 2024-07-13 | Routine inspection completed. No issues found. |
| INSP-00011 | Aligned | 7.4 | false | SG-126D | 2023-08-20 | Emily Chen | SanAntonio-Central | CPT-D1 | 0.6 | 13.9 | 16.1 | 44.4 | 2024-08-24 | Routine inspection completed. No issues found. |
| INSP-00012 | Aligned | 6.7 | false | SG-127E | 2023-09-05 | Mason Clark | ElPaso-Substation3 | CPT-E1 | 0.9 | 21.3 | 14.2 | 67.9 | 2024-09-10 | Routine inspection completed. No issues found. |
| INSP-00013 | Aligned | 6.55 | false | SG-128F | 2023-09-29 | Layla Morgan | Amarillo-EastYard | CPT-F3 | 2.9 | 23.8 | 17.1 | 89.6 | 2024-09-29 | Routine inspection completed. No issues found. |
| INSP-00014 | Aligned | 6.34 | false | SG-129G | 2023-10-10 | David Cole | Lubbock-WestField | CPT-G3 | 1.1 | 16.7 | 15.8 | 72.5 | 2024-10-10 | Routine inspection completed. No issues found. |
| INSP-00015 | Aligned | 7.2 | false | SG-130H | 2023-10-21 | Julia Varga | Waco-SouthGrid | CPT-H1 | 0.3 | 13.8 | 12.8 | 49.1 | 2024-10-22 | Routine inspection completed. No issues found. |
| INSP-00016 | Aligned | 6.89 | false | SG-131J | 2023-11-06 | Leo Knight | Midland-CityCore | CPT-J2 | 1.7 | 19.1 | 19.7 | 82 | 2024-11-06 | Routine inspection completed. No issues found. |
| INSP-00017 | Aligned | 7.42 | false | SG-132K | 2023-12-02 | Paige Nelson | CorpusChristi-Port | CPT-K1 | 0 | 12.2 | 10.6 | 33.5 | 2024-12-02 | Routine inspection completed. No issues found. |
| INSP-00018 | Aligned | 6.48 | false | SG-133L | 2023-12-13 | Henry Kim | FortWorth-North | CPT-L2 | 1.9 | 21.7 | 14.4 | 105.3 | 2024-06-14 | Slight increase in moisture/PD. Recommend closer monitoring. |
| INSP-00019 | Aligned | 6.22 | false | SG-130H | 2024-01-08 | Nina Singh | Waco-SouthGrid | CPT-H3 | 2.4 | 28.6 | 18.9 | 150.4 | 2024-07-10 | Slight increase in moisture/PD. Recommend closer monitoring. |
| INSP-00020 | Aligned | 6.61 | false | SG-131J | 2024-01-24 | Carlos Rivera | Midland-CityCore | CPT-J1 | 2.3 | 25.4 | 20 | 170.1 | 2024-07-28 | Slight increase in moisture/PD. Recommend closer monitoring. |
What the 400 rows show
from the 400-row sampleNot Checked (contact alignment status) stands out: mean sf6_
- 7%action_
required = true - 6.9median sf6_
pressure_ bar - 98switchgears
- 98compartments
- 0.50median sf6_
leak_ ppm - 16.2median partial_
discharge_ acoustic_ db
Median 6.9, from 0.0 to 7.7.
- string 7
- float 5
- date 2
- boolean 1
Columns
15 columns in four groups| column | type | description | example |
|---|---|---|---|
| Text 7 columns | |||
inspection_id | string | Unique identifier for each GIS inspection recordunique | INSP-00001 |
switchgear_id | string | Unique identifier for the gas insulated switchgear unit | SG-123A |
inspector_name | string | Full name of the inspector conducting the inspection | Victor Pearson |
location_site | string | Name or code of the site where the switchgear is located | Dallas-NorthHub |
compartment_id | string | Identifier for the specific compartment within the switchgear | CPT-A1 |
contact_alignment_status | string | Status of contact alignment verification (e.g., 'Aligned', 'Misaligned', 'Not Checked')Aligned · Misaligned · Not Checked | Aligned |
remarks | string | Additional comments or observations from the inspectionoptional | Routine inspection comple… |
| Numbers 5 columns | |||
sf6_leak_ppm | float | Measured SF6 gas leak concentration in ppm-m (parts per million-meter)0 or more | 0 |
sf6_pressure_bar | float | Measured SF6 gas pressure in bar0 or more | 6.84 |
partial_discharge_acoustic_db | float | Partial discharge acoustic sensor reading in decibels (dB)0 or more · optional | 15.3 |
partial_discharge_uhf_db | float | Partial discharge UHF sensor reading in decibels (dB)0 or more · optional | 13.7 |
compartment_moisture_ppm | float | Measured moisture level in the compartment in ppm (parts per million)0 or more · optional | 56.2 |
| Dates and times 2 columns | |||
inspection_date | date | Date when the inspection was conducted | 2023-01-14 |
next_maintenance_date | date | Scheduled date for the next maintenance or inspectionoptional | 2024-01-15 |
| True or false 1 column | |||
action_required | boolean | Indicates if any corrective action is required based on inspection results | false |
Use it for
An energy dashboard
The action_
required rate and sf6_ pressure_ bar by contact_ alignment_ status. Excel, Power BI or Tableau. Why do the 39 Not Checked rows have a mean sf6_
pressure_ bar of 0.72? A root-cause class exercise
Hand out the rows and one question. The answer is in the data, not in the brief.
- Inspections400INSP-000016.84AlignedINSP-000421.9Misalign…INSP-000432.3Misalign…
A software demo
Believable inspections with switchgear_
id, inspection_ date and inspector_ name to fill a screen in front of a buyer.
blueprint · gas-insulated-switchgear-gis-inspection-and-sf6-leak-detection
Behind this dataset
Same schema. As many rows as you need.
These 400 rows came out of a blueprint — 15 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- GIS bay ID, manufacturer, and rated voltage (72.5kV-550kV typical)
- SF6 gas pressure per compartment (psig) and alarm thresholds
- Leak detection: infrared camera, sniffer probe (ppm-m sensitivity)
- Annual leak rate: <0.5% of gas inventory per year target
- Partial discharge monitoring: acoustic sensors, UHF antennas
- Moisture content in SF6 gas (ppm, <150ppm typical)
- Contact alignment and travel measurements
- Environmental regulations: SF6 greenhouse gas emissions reporting (EPA)
1 credit per row. Preview 20 rows free. Buy rows for the full run.
- Exports
- CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
- Licence
- yours to use, including commercially
- API slug
- gas-insulated-switchgear-gis-inspection-and-sf6-leak-detection