Circuit Breaker Timing and Contact Wear Analysis
This dataset provides detailed records of circuit breaker maintenance tests, including timing measurements, contact resistance, SF6 gas pressure, operating mechanism assessments, and contact wear. It enables reliability analysis, predictive maintenance, and asset management for electrical substations and power grids.
Sample rows
preview · 8 of 1,000 rows · all 15 columns| test_idstring | operating_mechanism_conditionstring | contact_wear_percentfloat | manufacturerstring | breaker_idstring | locationstring | modelstring | test_datedate | contact_travel_time_msfloat | opening_time_msfloat | closing_time_msfloat | contact_resistance_micro_ohmfloat | sf6_gas_pressure_mpafloat | technician_namestring | remarksstring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CBT10001 | Good | 21.3 | ABB | BRK0001 | Central Substation | Emax2-T4 | 2024-03-09 | 32.5 | 70.2 | 68.1 | 71.2 | 0.39 | Alex Kim | Routine inspection. All parameters normal. |
| CBT10002 | Good | 18.9 | Siemens | BRK0002 | East Valley Station | 3WL-1600 | 2024-03-08 | 36.7 | 74.4 | 71.5 | 85.9 | 0.42 | Morgan Lee | Breaker in excellent condition. |
| CBT10003 | Needs Maintenance | 31.1 | GE | BRK0003 | West Ridge Hub | EntelliGuard G | 2024-02-27 | 25.2 | 61.8 | 65.3 | 77.4 | 0.36 | Sonia Patel | Slightly elevated contact wear. Schedule maintenance. |
| CBT10004 | Good | 24.6 | Schneider | BRK0004 | North Point Yard | Masterpact NW | 2024-03-03 | 37.6 | 79 | 75.8 | 95.1 | 0.41 | Chris Wong | No issues detected. |
| CBT10005 | Good | 26.7 | Mitsubishi | BRK0005 | South Gate Facility | AE-SW | 2024-01-29 | 41.3 | 80.5 | 82.1 | 103.9 | 0.38 | Derek Evans | Breaker operating within normal parameters. |
| CBT10006 | Faulty | 89.5 | ABB | BRK0001 | Central Substation | Emax2-T4 | 2024-02-18 | 110.2 | 218.4 | 210.7 | 400 | 0.12 | Alex Kim | Major fault detected. Immediate replacement required. |
| CBT10007 | Good | 14.2 | Hitachi | BRK0006 | Lakeside Unit | HV-2000 | 2024-03-12 | 27.8 | 66.9 | 62.2 | 80.7 | 0.33 | Rachel Tan | Routine test, all results satisfactory. |
| CBT10008 | Good | 19.8 | Siemens | BRK0002 | East Valley Station | 3WL-1600 | 2024-02-23 | 29.3 | 63.2 | 69.4 | 82.6 | 0.44 | Morgan Lee | All measurements within range. |
| CBT10009 | Good | 28.4 | GE | BRK0007 | Riverbend Substation | EntelliGuard G | 2024-03-01 | 34 | 70.7 | 72.1 | 92.3 | 0.4 | Timothy Duran | Inspection passed. No action needed. |
| CBT10010 | Needs Maintenance | 34.6 | Schneider | BRK0008 | Hilltop Station | Masterpact NW | 2024-02-16 | 38.9 | 77.3 | 77.8 | 99.7 | 0.43 | Chris Wong | Contact wear starting to trend up. |
| CBT10011 | Faulty | 95 | Siemens | BRK0002 | East Valley Station | 3WL-1600 | 2024-01-26 | 115 | 220 | 215 | 399 | 0.09 | Morgan Lee | Critical wear detected. Immediate shutdown. |
| CBT10012 | Good | 13.7 | Mitsubishi | BRK0009 | Metro Center | AE-SW | 2024-03-10 | 22.1 | 59.4 | 63.7 | 60.8 | 0.38 | Derek Evans | All readings nominal. |
| CBT10013 | Good | 25.2 | GE | BRK0003 | West Ridge Hub | EntelliGuard G | 2024-03-06 | 40.5 | 84.2 | 80.6 | 102.4 | 0.42 | Sonia Patel | Breaker passed all tests. |
| CBT10014 | Needs Maintenance | 30.5 | ABB | BRK0010 | Summit Yard | Emax2-T4 | 2024-02-24 | 33.7 | 68 | 73.2 | 87.6 | 0.35 | Alex Kim | Some wear observed, schedule service. |
| CBT10015 | Good | 17.8 | Schneider | BRK0004 | North Point Yard | Masterpact NW | 2024-03-11 | 28.6 | 62.9 | 67.4 | 79.2 | 0.37 | Chris Wong | Breaker in very good shape. |
| CBT10016 | Good | 27.3 | Mitsubishi | BRK0005 | South Gate Facility | AE-SW | 2024-02-20 | 44.1 | 83.6 | 81.2 | 108.4 | 0.39 | Derek Evans | Normal wear, no action needed. |
| CBT10017 | Good | 15.4 | Hitachi | BRK0006 | Lakeside Unit | HV-2000 | 2024-02-25 | 30 | 65.6 | 66.3 | 81.6 | 0.34 | Rachel Tan | System check completed. |
| CBT10018 | Good | 29.1 | GE | BRK0007 | Riverbend Substation | EntelliGuard G | 2024-02-21 | 31.2 | 69.2 | 70.9 | 88.7 | 0.39 | Timothy Duran | Breaker in normal operating condition. |
| CBT10019 | Needs Maintenance | 35.9 | Schneider | BRK0008 | Hilltop Station | Masterpact NW | 2024-03-02 | 39.7 | 78.1 | 76.3 | 101.2 | 0.4 | Chris Wong | Wear trending up, plan service soon. |
| CBT10020 | Faulty | 90.8 | ABB | BRK0001 | Central Substation | Emax2-T4 | 2024-01-31 | 113.8 | 219.3 | 213.2 | 398.7 | 0.1 | Alex Kim | Breaker failed test, urgent replacement advised. |
What the 1,000 rows show
from the 1,000-row sampleFaulty (operating mechanism condition) stands out: mean contact_
- 25.3median contact_
wear_ percent - 145models
- 173locations
- 205technician names
- 206breakers
- 38.5median contact_
travel_ time_ ms
Median 25.3, from 0.0 to 100.0.
- string 8
- float 6
- date 1
Columns
15 columns in three groups| column | type | description | example |
|---|---|---|---|
| Text 8 columns | |||
test_id | string | Unique identifier for each maintenance test recordunique | CBT10001 |
breaker_id | string | Unique identifier for the circuit breaker being tested | BRK0001 |
location | string | Physical location or substation of the circuit breaker | Central Substation |
manufacturer | string | Manufacturer of the circuit breakeroptional | ABB |
model | string | Model number or name of the circuit breakeroptional | Emax2-T4 |
operating_mechanism_condition | string | Condition assessment of the operating mechanism (e.g., Good, Needs Maintenance, Faulty)Good · Needs Maintenance · Faulty · Unknown | Good |
technician_name | string | Name of the technician who performed the testoptional | Alex Kim |
remarks | string | Additional notes or remarks about the test or breaker conditionoptional | No issues detected. |
| Numbers 6 columns | |||
contact_travel_time_ms | float | Measured time for the contacts to travel during operation (milliseconds)0 or more | 32.5 |
opening_time_ms | float | Time taken for the breaker to open (milliseconds)0 or more | 70.2 |
closing_time_ms | float | Time taken for the breaker to close (milliseconds)0 or more | 68.1 |
contact_resistance_micro_ohm | float | Measured contact resistance in micro-ohms0 or more | 71.2 |
sf6_gas_pressure_mpa | float | SF6 gas pressure in MegaPascals at the time of test0 or more | 0.39 |
contact_wear_percent | float | Percentage of contact wear measured during the test0 to 100 | 21.3 |
| Dates and times 1 column | |||
test_date | date | Date when the maintenance test was performed | 2024-03-09 |
Use it for
An energy dashboard
Contact_
wear_ percent by operating_ mechanism_ condition and a breakdown of manufacturer. Excel, Power BI or Tableau. Why do the 104 Faulty rows have a mean contact_
wear_ percent of 70.8? A root-cause class exercise
Hand out the rows and one question. The answer is in the data, not in the brief.
- Tests1,000CBT1000121.3GoodCBT1000218.9GoodCBT1000331.1Needs Ma…
A software demo
Believable tests with breaker_
id, location and manufacturer to fill a screen in front of a buyer.
blueprint · circuit-breaker-timing-and-contact-wear-analysis
Behind this dataset
Same schema. As many rows as you need.
These 1,000 rows came out of a blueprint — 15 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- Breaker ID, manufacturer (ABB, Siemens, GE, etc.), and rated voltage/current
- Test date and operations count since last maintenance
- Opening time (cycles at 60Hz, typically 2-5 cycles target)
- Closing time and reclose time for reclosing breakers
- Contact resistance per phase (micro-ohms, <100µΩ typical)
- SF6 gas pressure (psig) and moisture content (ppm)
- Operating mechanism: spring, hydraulic, pneumatic condition
- Contact wear measurement and replacement threshold