Voltage Quality and Power Outage Duration Monitoring

This dataset provides granular, timestamped records of voltage quality events and power outages as detected by AMI meters, including detailed event types, IEEE 1159 classifications, voltage/frequency measurements, durations, and geospatial information. It enables utilities and researchers to analyze grid reliability, identify outage patterns, and improve power quality management.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Grid reliability and outage analysis

Sample rows

preview · 8 of 130 rows · all 17 columns
event_idstringevent_typestringvoltage_maxfloatieee_1159_classificationstringmeter_idstringevent_timestampdatetimevoltage_minfloatvoltage_nominalfloatfrequencyfloatduration_secondsfloatoutage_causestringrestoration_timestampdatetimelocation_streetstringlocation_citystringlocation_statestringlocation_postal_codestringlocation_countrystring
EVT10001voltage_sag116.2momentaryMTR900012024-05-01T08:15:22Z98.512060.51.32blankblank123 Broad StDallasTX75201USA
EVT10002momentary_interruptionblankinstantaneousMTR900022024-05-02T15:09:33Zblank12059.82.05weather2024-05-02T15:09:35Z47 Main AveChicagoIL60605USA
EVT10003sustained_outage0sustainedMTR900032024-05-03T03:42:08Z023005400major storm2024-05-03T05:12:08Z5 Rue LafayetteParisÎle-de-France75009France
EVT10004voltage_swell265.8temporaryMTR900042024-05-04T11:25:45Z239.224060.12.09blankblank14 Queen StLondonEnglandSW1A2AAUK
EVT10005frequency_deviation120.6instantaneousMTR900052024-05-04T21:18:14Z120.112063.10.29grid instabilityblank201 Lake DrOrlandoFL32801USA
EVT10006voltage_sag117.8momentaryMTR900062024-05-05T07:27:56Z110.412059.61.02blankblank8821 Maple StSeattleWA98101USA
EVT10007momentary_interruptionblankmomentaryMTR900072024-05-05T12:12:30Zblank24050.40.66tree contact2024-05-05T12:12:31Z9 Park CresBrisbaneQueensland4000Australia
EVT10008sustained_outage0temporaryMTR900082024-05-06T16:20:17Z0110029820equipment failure2024-05-07T00:27:17Z2 Shibuya CrossingTokyoTokyo150-0002Japan

What the 130 rows show

from the 130-row sample

Sustained_outage (event type) stands out: mean voltage_max is 0.0, against 152.8 for the rest.

  • 120.2median voltage_max
  • 8location countries
  • 10outage causes
  • 115.4median voltage_min
  • 120median voltage_nominal
  • 59.6median frequency
Mean voltage_max by event_type103 rows
0100200118.3voltage_…27 rows176.1voltage_…26 rows0.0sustaine…24 rows165.4frequenc…26 rows
voltage_max103 rows, in bands of 50
030602505801460150300voltage_max →

Median 120.2, from 0.0 to 265.8.

ieee_1159_classification128 rows with a value · 2 left blank
  1. instantaneous43
  2. momentary35
  3. temporary28
  4. sustained22
17 columns by typefrom the column list below
  • string 10
  • float 5
  • datetime 2

Columns

17 columns in three groups
blueprint · 17 columns
columntypedescriptionexample
Text 10 columns
event_idstringUnique identifier for each power quality event recorded by an AMI meteruniqueEVT10001
meter_idstringUnique identifier for the AMI meter reporting the eventMTR90001
event_typestringType of power quality event (e.g., voltage sag, voltage swell, momentary interruption, sustained outage, frequency deviation)5 valuesvoltage_sag
ieee_1159_classificationstringIEEE 1159 standard classification for the event (e.g., instantaneous, momentary, temporary, sustained)instantaneous · momentary · temporary · sustained · optionalmomentary
outage_causestringReported cause of outage or interruption (e.g., equipment failure, weather, unknown)10 causes · optionalweather
location_streetstringStreet address of the AMI meteroptional123 Broad St
location_citystringCity where the AMI meter is locatedoptionalDallas
location_statestringState or province where the AMI meter is locatedoptionalTX
location_postal_codestringPostal code of the AMI meter locationoptional75201
location_countrystringCountry of the AMI meter location8 countries · optionalUSA
Numbers 5 columns
voltage_minfloatMinimum voltage measured during the event (in volts)0 or more · optional98.5
voltage_maxfloatMaximum voltage measured during the event (in volts)0 or more · optional116.2
voltage_nominalfloatNominal voltage for the meter (in volts)0 or more · optional120
frequencyfloatMeasured frequency during the event (in Hz)0 or more · optional60.5
duration_secondsfloatDuration of the event in seconds0 or more · optional1.32
Dates and times 2 columns
event_timestampdatetimeDate and time when the power quality event occurred2024-05-01T08:15:22Z
restoration_timestampdatetimeTimestamp when power was restored after an outage (if applicable)optional2024-05-02T15:09:35Z

Use it for

  • median voltage…120.2103 rowsmean voltage max by e…118.3volt…176.1volt…0.0sust…165.4freq…

    An energy dashboard

    Voltage_max by event_type and a breakdown of ieee_1159_classification. Excel, Power BI or Tableau.

  • Why do the 24 sustained_outage rows have a mean voltage_max of 0.0?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable events with meter_id, event_timestamp and event_type to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 17 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset130 rows17 columns
Yours1,000 rows17 columnslocation_street: UK only

blueprint · voltage-quality-and-power-outage-duration-monitoring

Behind this dataset

Same schema. As many rows as you need.

These 130 rows came out of a blueprint — 17 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • Event timestamp and meter ID
  • Voltage magnitude in volts (phase A, B, C for 3-phase)
  • Event type per IEEE 1159: sag (<90%), swell (>110%), interruption (<10%)
  • Duration in cycles (1 cycle = 16.67ms at 60Hz) or seconds
  • RMS voltage calculation over 1-cycle or 10-minute windows
  • Frequency deviation from nominal 60Hz (±0.1Hz normal range)
  • Cause code: tree contact, animal, equipment failure, lightning
  • Customer notification for sustained outages (>5 minutes)
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
voltage-quality-and-power-outage-duration-monitoring