Distribution Automation and Feeder Remote Terminal Units

This dataset provides comprehensive SCADA event records from distribution feeder RTUs, detailing recloser operations, capacitor bank switching, voltage regulator tap changes, and automation scheme actions. It includes device-level measurements, event metadata, and operational context, enabling advanced grid analytics, reliability studies, and automation performance tracking for electric utilities.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Grid reliability and outage analysis

Sample rows

preview · 8 of 120 rows · all 18 columns
rtu_idstringdevice_typestringoperation_valuefloatevent_typestringfeeder_idstringlocation_namestringlatitudefloatlongitudefloatevent_idstringevent_timestampdatetimedevice_idstringoperation_statusstringvoltagefloatcurrentfloatpower_factorfloatautomation_scheme_idstringoperator_idstringremarksstring
RTU001recloserblankrecloser_operationFD10001Central Substation34.0522-118.2437EVT2024010012024-01-12T08:30:10RECL-001open12345245.70.97AS001SYS_TRIGRoutine open sequence, triggered by automation
RTU002capacitor_bank320.5capacitor_bank_switchingFD10002Downtown Commercial40.7128-74.006EVT2024010022024-01-13T09:15:22CAPB-002switched12860370.10.89AS002SCADA_COREAutomated kVAR adjustment due to peak load
RTU003voltage_regulator8voltage_regulator_tapFD10003Remote Rural Site47.6062-122.3321EVT2024010032024-01-15T19:22:46VREG-003tap_changed1211062.50.74blankOP101Manual tap adjustment for seasonal voltage
RTU004capacitor_bank480capacitor_bank_switchingFD10001Industrial Park North35.6895139.6917EVT2024010042024-01-16T13:44:08CAPB-004switched132004050.93AS003OP102High kVAR switching, industrial backup required
RTU005voltage_regulator2voltage_regulator_tapFD10004Suburban Block33.4484-112.074EVT2024010052024-01-18T21:02:35VREG-005tap_changed1295082.30.91blankOP103Routine tap change, mid-range seasonal adjustment
RTU006recloserblankrecloser_operationFD10005Offshore Wind Hub51.50740.1278EVT2024010062024-01-19T00:00:00RECL-006closed13490199.90.99blankOP104Boundary recloser closure, edge case
RTU007capacitor_bank410.2capacitor_bank_switchingFD10002Medical Campus East42.3601-71.0589EVT2024010072024-01-20T05:18:27CAPB-007switched12680366.40.84AS004SYS_AUTOBackup capacitor bank switching
RTU008voltage_regulator16voltage_regulator_tapFD10006blank-90180EVT2024010082024-01-21T23:59:59VREG-008tap_changed99999999.9-1blankOP999Outlier event, boundary voltage and current

What the 120 rows show

from the 120-row sample
  • 16.0median operation_value
  • 4operation statuses
  • 12,770median voltage
  • 151.4median current
  • 0.89median power_factor
device_type120 rows by value
0255041recloser34%37capacitor_ba…31%42voltage_regu…35%
operation_value78 rows, in bands of 1,000
040807100000000705,00010koperation_value →

Median 16.0, from 0.0 to 10,000.

event_type120 rows · 4 values
  1. recloser_operation39
  2. voltage_regulator_tap38
  3. capacitor_bank_switching32
  4. automation_scheme_action11
18 columns by typefrom the column list below
  • string 11
  • float 6
  • datetime 1

Columns

18 columns in three groups
blueprint · 18 columns
columntypedescriptionexample
Text 11 columns
rtu_idstringUnique identifier for the feeder Remote Terminal Unit (RTU)uniqueRTU001
feeder_idstringUnique identifier for the feeder circuit associated with the RTUFD10001
location_namestringName or description of the RTU installation locationoptionalCentral Substation
event_idstringUnique identifier for the SCADA event recorded by the RTUuniqueEVT202401001
event_typestringType of event (e.g., recloser_operation, capacitor_bank_switching, voltage_regulator_tap, automation_scheme_action)4 valuesrecloser_operation
device_idstringUnique identifier for the device involved in the event (e.g., recloser, capacitor bank, voltage regulator)RECL-001
device_typestringType of device involved (e.g., recloser, capacitor_bank, voltage_regulator)recloser · capacitor_bank · voltage_regulatorrecloser
operation_statusstringStatus of the operation (e.g., open, closed, switched, tap_changed)open · closed · switched · tap_changedopen
automation_scheme_idstringIdentifier for the distribution automation scheme involved in the eventoptionalAS001
operator_idstringIdentifier for the operator or system that initiated the eventoptionalSYS_TRIG
remarksstringAdditional notes or remarks about the eventoptionalSeasonal tap reset
Numbers 6 columns
latitudefloatLatitude coordinate of the RTU location-90 to 90 · optional34.0522
longitudefloatLongitude coordinate of the RTU location-180 to 180 · optional-118.2437
operation_valuefloatValue associated with the operation (e.g., tap position, switched kVAR, etc.)optional320.5
voltagefloatMeasured voltage at the time of event (in volts)0 or more · optional12345
currentfloatMeasured current at the time of event (in amperes)0 or more · optional245.7
power_factorfloatMeasured power factor at the time of event-1 to 1 · optional0.97
Dates and times 1 column
event_timestampdatetimeDate and time when the event occurred2024-01-12T08:30:10

Use it for

  • median operati…16.078 rowsrows by device type41reclos…37capaci…42voltag…

    An energy dashboard

    Operation_value by device_type and a breakdown of event_type. Excel, Power BI or Tableau.

  • What pattern can you find in 120 rows?

    A class exercise

    Hand out the rows and one question. Everyone works from the same 120 rows.

  • A software demo

    Believable rtus with feeder_id, location_name and latitude to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 18 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset120 rows18 columns
Yours1,000 rows18 columnslocation_name: UK only

blueprint · distribution-automation-and-feeder-remote-terminal-units

Behind this dataset

Same schema. As many rows as you need.

These 120 rows came out of a blueprint — 18 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • RTU ID and feeder identification
  • Recloser operations: open, close, lockout
  • Recloser shot count for maintenance prediction
  • Capacitor bank status: in-service, out-of-service
  • Voltage regulator tap position
  • Feeder head voltage and current
  • Load profile at feeder level
  • Fault indicators: permanent vs temporary faults
Rows
Open the blueprint in Data Factory