Network Contingency Analysis Results

This dataset provides detailed results from power grid contingency analysis, covering N-1 and N-2 scenarios, post-contingency flows, voltage and thermal violations, and recommended corrective actions. It enables planners and engineers to assess grid reliability, identify vulnerabilities, and evaluate mitigation strategies for operational and planning purposes.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Grid reliability assessment and vulnerability analysis

Sample rows

preview · 8 of 105 rows · all 17 columns
contingency_idstringcorrective_action_typestringvoltage_violation_value_kvfloatvoltage_violationbooleanmonitored_element_typestringscenario_typestringelement_outaged_1stringelement_outaged_2stringanalysis_datetimedatetimepost_contingency_flow_mwfloatpost_contingency_voltage_kvfloatthermal_overloadbooleanthermal_overload_value_mvafloatcorrective_action_requiredbooleanmonitored_element_idstringplanning_areastringcorrective_action_detailsstring
CNG-00001blankblankfalselineN-1LN-105blank2024-06-13T10:23:00Z152.7312.5falseblankfalseLN-105Northern Metro Gridblank
CNG-00002generation redispatch8.7truetransformerN-2TR-212LN-2232024-05-29T16:15:00Z765.3220.1true34.6trueTR-212Sanford Industrial ZoneRedispatch 120 MW from South Generators to mitigate overload and restore voltage margin.
CNG-00003blankblankfalsebusN-1BS-09blank2024-06-07T09:45:00Z80.2110.3falseblankfalseBS-09Western Plains Districtblank
CNG-00004network switchingblankfalsetransformerN-2LN-118TR-2082024-04-18T15:02:00Z398.5205.9true27.1trueTR-208Central Valley RegionSwitch parallel transformer TR-204 into service to relieve overload on TR-208.
CNG-00005blankblankfalsetransformerN-1TR-310blank2024-06-12T13:54:00Z302.4388.6falseblankfalseTR-310East Bay Expansionblank
CNG-00006blankblankfalselineN-1LN-119blank2024-06-14T11:32:00Z488.8401.2falseblankfalseLN-119Silver Lake Corridorblank
CNG-00007generation redispatch19.2truebusN-2BS-22LN-1272024-02-20T08:00:00Z505.6212.7true50trueBS-22Highland Industrial LoopRedispatch generation at Bus 22 to mitigate voltage violation and relieve thermal stress.
CNG-00008blankblankfalselineN-1LN-110blank2024-06-11T07:20:00Z115.9123.3falseblankfalseLN-110Southside Networkblank

What the 105 rows show

from the 105-row sample

Load shedding (corrective action type) stands out: mean voltage_violation_value_kv is 52.1, against 2.6 for the rest.

  • 33%voltage_violation = true
  • 1.0median voltage_violation_value_kv
  • 2scenario types
  • 397.1median post_contingency_flow_mw
  • 225.4median post_contingency_voltage_kv
  • 38.2median thermal_overload_value_mva
Mean voltage_violation_value_kv by corrective_action_type35 rows
0408013.0generation r…4 rows52.1load shedding12 rows0.44network swit…19 rows
voltage_violation_value_kv35 rows, in bands of 10
01530212012903060voltage_violation_value_kv →

Median 1.0, from 0.07 to 58.7.

monitored_element_type105 rows · 3 values
  1. line39
  2. transformer38
  3. bus28
17 columns by typefrom the column list below
  • string 9
  • float 4
  • datetime 1
  • boolean 3

Columns

17 columns in four groups
blueprint · 17 columns
columntypedescriptionexample
Text 9 columns
contingency_idstringUnique identifier for each contingency scenario analyzeduniqueCNG-00001
scenario_typestringType of contingency scenario (e.g., N-1, N-2)N-1 · N-2N-1
element_outaged_1stringIdentifier of the first network element outaged in the scenarioLN-105
element_outaged_2stringIdentifier of the second network element outaged in N-2 scenarios; null for N-1optionalLN-223
corrective_action_typestringType of corrective action recommended (e.g., generation redispatch, load shedding, switching); null if not required4 values · optionalgeneration redispatch
corrective_action_detailsstringDetailed description of the recommended corrective action; null if not requiredoptionalRedispatch 120 MW from So…
monitored_element_idstringIdentifier of the network element (line, transformer, bus) being monitored for violationsLN-105
monitored_element_typestringType of monitored element (e.g., line, transformer, bus)line · transformer · busline
planning_areastringName or code of the planning area or region analyzedNorthern Metro Grid
Numbers 4 columns
post_contingency_flow_mwfloatPost-contingency power flow in megawatts (MW) for the monitored element0 or more152.7
post_contingency_voltage_kvfloatPost-contingency voltage in kilovolts (kV) at the monitored bus0 or more312.5
voltage_violation_value_kvfloatAmount of voltage violation in kilovolts (if any); null if no violationoptional8.7
thermal_overload_value_mvafloatAmount of thermal overload in MVA (if any); null if no overloadoptional34.6
Dates and times 1 column
analysis_datetimedatetimeTimestamp when the contingency analysis was performed2024-06-13T10:23:00Z
True or false 3 columns
voltage_violationbooleanIndicates if a voltage violation occurred (true/false)false
thermal_overloadbooleanIndicates if a thermal overload occurred (true/false)false
corrective_action_requiredbooleanIndicates if any corrective action is required for this contingencyfalse

Use it for

  • voltage violat…33%35 of 105 rowsmean voltage violatio…13.0genera…52.1load s…0.44networ…

    An energy dashboard

    The voltage_violation rate, voltage_violation_value_kv by corrective_action_type and a breakdown of monitored_element_type. Excel, Power BI or Tableau.

  • Why do the 12 load shedding rows have a mean voltage_violation_value_kv of 52.1?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable contingencies with scenario_type, element_outaged_1 and element_outaged_2 to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 17 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset105 rows17 columns
Yours1,000 rows17 columns

blueprint · network-contingency-analysis-results

Behind this dataset

Same schema. As many rows as you need.

These 105 rows came out of a blueprint — 17 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • Contingency ID unique per scenario
  • Contingency type: single element (N-1), double element (N-2), common mode
  • Outaged element: line, transformer, generator
  • Post-contingency power flows
  • Voltage violations: buses outside limits (typically ±5%)
  • Thermal overloads: elements above emergency rating
  • Convergence status of power flow solution
  • Severity index or ranking
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
network-contingency-analysis-results

What should your data show?

Preview 20 rows free
No signup. No card.