Network Contingency Analysis Results
This dataset provides detailed results from power grid contingency analysis, covering N-1 and N-2 scenarios, post-contingency flows, voltage and thermal violations, and recommended corrective actions. It enables planners and engineers to assess grid reliability, identify vulnerabilities, and evaluate mitigation strategies for operational and planning purposes.
Sample rows
preview · 8 of 105 rows · all 17 columns| contingency_idstring | corrective_action_typestring | voltage_violation_value_kvfloat | voltage_violationboolean | monitored_element_typestring | scenario_typestring | element_outaged_1string | element_outaged_2string | analysis_datetimedatetime | post_contingency_flow_mwfloat | post_contingency_voltage_kvfloat | thermal_overloadboolean | thermal_overload_value_mvafloat | corrective_action_requiredboolean | monitored_element_idstring | planning_areastring | corrective_action_detailsstring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CNG-00001 | blank | blank | false | line | N-1 | LN-105 | blank | 2024-06-13T10:23:00Z | 152.7 | 312.5 | false | blank | false | LN-105 | Northern Metro Grid | blank |
| CNG-00002 | generation redispatch | 8.7 | true | transformer | N-2 | TR-212 | LN-223 | 2024-05-29T16:15:00Z | 765.3 | 220.1 | true | 34.6 | true | TR-212 | Sanford Industrial Zone | Redispatch 120 MW from South Generators to mitigate overload and restore voltage margin. |
| CNG-00003 | blank | blank | false | bus | N-1 | BS-09 | blank | 2024-06-07T09:45:00Z | 80.2 | 110.3 | false | blank | false | BS-09 | Western Plains District | blank |
| CNG-00004 | network switching | blank | false | transformer | N-2 | LN-118 | TR-208 | 2024-04-18T15:02:00Z | 398.5 | 205.9 | true | 27.1 | true | TR-208 | Central Valley Region | Switch parallel transformer TR-204 into service to relieve overload on TR-208. |
| CNG-00005 | blank | blank | false | transformer | N-1 | TR-310 | blank | 2024-06-12T13:54:00Z | 302.4 | 388.6 | false | blank | false | TR-310 | East Bay Expansion | blank |
| CNG-00006 | blank | blank | false | line | N-1 | LN-119 | blank | 2024-06-14T11:32:00Z | 488.8 | 401.2 | false | blank | false | LN-119 | Silver Lake Corridor | blank |
| CNG-00007 | generation redispatch | 19.2 | true | bus | N-2 | BS-22 | LN-127 | 2024-02-20T08:00:00Z | 505.6 | 212.7 | true | 50 | true | BS-22 | Highland Industrial Loop | Redispatch generation at Bus 22 to mitigate voltage violation and relieve thermal stress. |
| CNG-00008 | blank | blank | false | line | N-1 | LN-110 | blank | 2024-06-11T07:20:00Z | 115.9 | 123.3 | false | blank | false | LN-110 | Southside Network | blank |
| CNG-00009 | network switching | blank | false | transformer | N-2 | TR-312 | BS-14 | 2024-06-02T17:40:00Z | 702.5 | 315.8 | true | 21.9 | true | TR-312 | Greenridge Transmission | Switch BS-12 into service to redistribute load and relieve transformer TR-312. |
| CNG-00010 | blank | blank | false | bus | N-1 | BS-07 | blank | 2024-06-09T06:10:00Z | 95.4 | 135.2 | false | blank | false | BS-07 | Clayton Urban Hub | blank |
| CNG-00011 | blank | blank | false | line | N-1 | LN-122 | blank | 2024-05-04T20:48:00Z | 251.8 | 211.7 | false | blank | false | LN-122 | Riverbend Power Park | blank |
| CNG-00012 | load shedding | 33.2 | true | line | N-2 | LN-121 | TR-316 | 2024-06-06T19:46:00Z | 899.2 | 225.8 | true | 129.6 | true | LN-121 | Eastside Industrial Belt | Initiate emergency load shedding in zones 3 and 4 to rapidly reduce demand and restore voltage. |
| CNG-00013 | blank | blank | false | transformer | N-1 | TR-301 | blank | 2024-06-13T15:55:00Z | 370.3 | 346.5 | false | blank | false | TR-301 | Lakeview Subregion | blank |
| CNG-00014 | generation redispatch | blank | false | bus | N-2 | BS-31 | LN-130 | 2024-03-17T13:29:00Z | 602 | 203.1 | true | 44.8 | true | BS-31 | Sunset Heights Area | Adjust generator outputs at Bus 31 and Bus 33 to alleviate transformer overload. |
| CNG-00015 | blank | blank | false | line | N-1 | LN-131 | blank | 2024-06-01T21:13:00Z | 72.5 | 104.9 | false | blank | false | LN-131 | Midtown Transmission | blank |
| CNG-00016 | load shedding | 54.7 | true | line | N-2 | TR-318 | LN-150 | 2024-06-04T14:23:00Z | 9822.1 | 765 | true | 398.2 | true | LN-150 | Urban North Expansion | Emergency curtailment across all zones to prevent cascading outages due to extreme conditions. |
| CNG-00017 | blank | blank | false | bus | N-1 | BS-27 | blank | 2024-06-03T07:08:00Z | 99.9 | 117.6 | false | blank | false | BS-27 | Downtown Grid | blank |
| CNG-00018 | network switching | 1.2 | true | bus | N-2 | LN-134 | BS-19 | 2024-05-21T22:21:00Z | 702.4 | 223.5 | false | blank | true | BS-19 | Westside Manufacturing | Switch Bus 21 into the network to support supply and improve voltage at Bus 19. |
| CNG-00019 | blank | blank | false | transformer | N-1 | TR-324 | blank | 2024-06-10T17:41:00Z | 401.9 | 355.4 | false | blank | false | TR-324 | Southport Distribution | blank |
| CNG-00020 | generation redispatch | blank | false | line | N-2 | LN-143 | LN-144 | 2024-06-05T20:30:00Z | 814.3 | 277.2 | true | 37.8 | true | LN-143 | East Industrial Crescent | Redispatch 80 MW from LN-145 area generators to relieve line overload. |
What the 105 rows show
from the 105-row sampleLoad shedding (corrective action type) stands out: mean voltage_
- 33%voltage_
violation = true - 1.0median voltage_
violation_ value_ kv - 2scenario types
- 397.1median post_
contingency_ flow_ mw - 225.4median post_
contingency_ voltage_ kv - 38.2median thermal_
overload_ value_ mva
Median 1.0, from 0.07 to 58.7.
- string 9
- float 4
- datetime 1
- boolean 3
Columns
17 columns in four groups| column | type | description | example |
|---|---|---|---|
| Text 9 columns | |||
contingency_id | string | Unique identifier for each contingency scenario analyzedunique | CNG-00001 |
scenario_type | string | Type of contingency scenario (e.g., N-1, N-2)N-1 · N-2 | N-1 |
element_outaged_1 | string | Identifier of the first network element outaged in the scenario | LN-105 |
element_outaged_2 | string | Identifier of the second network element outaged in N-2 scenarios; null for N-1optional | LN-223 |
corrective_action_type | string | Type of corrective action recommended (e.g., generation redispatch, load shedding, switching); null if not required4 values · optional | generation redispatch |
corrective_action_details | string | Detailed description of the recommended corrective action; null if not requiredoptional | Redispatch 120 MW from So… |
monitored_element_id | string | Identifier of the network element (line, transformer, bus) being monitored for violations | LN-105 |
monitored_element_type | string | Type of monitored element (e.g., line, transformer, bus)line · transformer · bus | line |
planning_area | string | Name or code of the planning area or region analyzed | Northern Metro Grid |
| Numbers 4 columns | |||
post_contingency_flow_mw | float | Post-contingency power flow in megawatts (MW) for the monitored element0 or more | 152.7 |
post_contingency_voltage_kv | float | Post-contingency voltage in kilovolts (kV) at the monitored bus0 or more | 312.5 |
voltage_violation_value_kv | float | Amount of voltage violation in kilovolts (if any); null if no violationoptional | 8.7 |
thermal_overload_value_mva | float | Amount of thermal overload in MVA (if any); null if no overloadoptional | 34.6 |
| Dates and times 1 column | |||
analysis_datetime | datetime | Timestamp when the contingency analysis was performed | 2024-06-13T10:23:00Z |
| True or false 3 columns | |||
voltage_violation | boolean | Indicates if a voltage violation occurred (true/false) | false |
thermal_overload | boolean | Indicates if a thermal overload occurred (true/false) | false |
corrective_action_required | boolean | Indicates if any corrective action is required for this contingency | false |
Use it for
An energy dashboard
The voltage_
violation rate, voltage_ violation_ value_ kv by corrective_ action_ type and a breakdown of monitored_ element_ type. Excel, Power BI or Tableau. Why do the 12 load shedding rows have a mean voltage_
violation_ value_ kv of 52.1? A root-cause class exercise
Hand out the rows and one question. The answer is in the data, not in the brief.
- Contingencies105CNG-00001—CNG-000028.7generati…CNG-0000719.2generati…
A software demo
Believable contingencies with scenario_
type, element_ outaged_ 1 and element_ outaged_ 2 to fill a screen in front of a buyer.
blueprint · network-contingency-analysis-results
Behind this dataset
Same schema. As many rows as you need.
These 105 rows came out of a blueprint — 17 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.
- Contingency ID unique per scenario
- Contingency type: single element (N-1), double element (N-2), common mode
- Outaged element: line, transformer, generator
- Post-contingency power flows
- Voltage violations: buses outside limits (typically ±5%)
- Thermal overloads: elements above emergency rating
- Convergence status of power flow solution
- Severity index or ranking