Transmission Lines and Conductors

This dataset provides detailed technical and operational parameters for transmission lines, including electrical characteristics, conductor specifications, tower details, right-of-way information, and protection system data. It is ideal for grid planning, load flow analysis, asset management, and protection coordination in the energy sector.

  • last updated 2 Nov 2025
  • by GoMask
The brief that made it

Load flow and short-circuit analysis for power system planning

Sample rows

preview · 8 of 100 rows · all 21 columns
line_idstringtower_typestringtower_height_mfloatis_protectedbooleanownerstringline_namestringfrom_substationstringto_substationstringvoltage_kvfloatlength_kmfloatimpedance_ohmfloatreactance_ohmfloatcapacitance_nffloatthermal_rating_ampfloatconductor_typestringconductor_size_mm2floatright_of_way_width_mfloatnumber_of_circuitsintegerprotection_typestringcommissioning_datedatenotesstring
TL-0001lattice32trueGridCorpCentral Valley MainSUBST_A01SUBST_B1422054.212.818.7640940ACSR400252distance2003-06-18Main corridor; annual inspection scheduled
TL-0002monopole18falseElectraGridWest Ridge SpurSUBST_W21SUBST_M0511018.55.47.2145540AAAC185151blank2016-04-14Urban feeder extension
TL-0003lattice39truePowerConnectEast Lake LinkSUBST_E09SUBST_D0233076.820.229.110501270ACSR600382differential1997-09-23Strategic interconnection
TL-0004monopole20trueUrbanPowerMetro NorthSUBST_N04SUBST_F0113222.168.4210580AAC225171distance2018-02-11blank
TL-0005lattice46truePowerConnectRiver CrossingSUBST_R02SUBST_S10500101.527.943.714501980ACSR1000522distance2010-08-29River span; high wind region
TL-0006lattice34falseGridCorpSouth OutfallSUBST_S15SUBST_O1122061.714.120.3820980AAAC500281blank2007-12-17blank
TL-0007monopole14falseEcoPowerGreenbelt LoopSUBST_G07SUBST_H116612.33.14.267240AAC9591blank2021-07-28Vegetated corridor
TL-0008lattice37trueGridCorpIndustrial SouthSUBST_I02SUBST_S2133044.613.821.49501230ACSR500322differential2005-03-11blank

What the 100 rows show

from the 100-row sample

Lattice (tower type) stands out: mean tower_height_m is 41.4, against 16.6 for the rest.

  • 64%is_protected = true
  • 30.1median tower_height_m
  • 3conductor types
  • 3protection types
  • 220median voltage_kv
  • 39.7median length_km
Mean tower_height_m by tower_type100 rows
0408041.4lattice52 rows16.6monopole48 rows
tower_height_m100 rows, in bands of 5
015302412822094885103560tower_height_m →

Median 30.1, from 10.0 to 59.5.

owner100 rows · top 10 of 40 values
  1. GridCorp19
  2. UrbanPower12
  3. PowerConnect8
  4. EcoPower8
  5. MetroGrid Solutions4
  6. ElectraGrid3
  7. Harbor Electric3
  8. Granite Transmission3
  9. Harmony Transmission3
  10. Pine Ridge Transmission2
21 columns by typefrom the column list below
  • string 9
  • integer 1
  • float 9
  • date 1
  • boolean 1

Columns

21 columns in four groups
blueprint · 21 columns
columntypedescriptionexample
Text 9 columns
line_idstringUnique identifier for the transmission lineuniqueTL-0001
line_namestringDescriptive name of the transmission lineCentral Valley Main
from_substationstringName or code of the originating substationSUBST_A01
to_substationstringName or code of the terminating substationSUBST_B14
conductor_typestringType/model of conductor used (e.g., ACSR, AAAC)3 typesACSR
tower_typestringType of tower structure (e.g., lattice, monopole)2 typeslattice
protection_typestringType of protection system used (e.g., distance, differential)3 types · optionaldistance
ownerstringOrganization or company that owns the transmission lineoptionalGridCorp
notesstringAdditional remarks or notes about the transmission lineoptionalUrban feeder extension
Numbers 10 columns
voltage_kvfloatNominal voltage rating of the line in kilovolts0 or more220
length_kmfloatLength of the transmission line in kilometers0 or more54.2
impedance_ohmfloatTotal impedance of the line in ohms0 or more12.8
reactance_ohmfloatTotal reactance of the line in ohms18.7
capacitance_nffloatTotal capacitance of the line in nanofarads0 or more · optional640
thermal_rating_ampfloatMaximum thermal current rating of the line in amperes0 or more940
conductor_size_mm2floatCross-sectional area of the conductor in square millimeters0 or more400
tower_height_mfloatHeight of the tower in meters0 or more · optional32
right_of_way_width_mfloatWidth of the right-of-way corridor in meters0 or more · optional25
number_of_circuitsintegerNumber of electrical circuits on the line1 or more2
Dates and times 1 column
commissioning_datedateDate when the transmission line was commissionedoptional2003-06-18
True or false 1 column
is_protectedbooleanIndicates if the line has protection systems installedtrue

Use it for

  • is protected64%64 of 100 rowsmean tower height m b…41.4lattice16.6monopo…

    An energy dashboard

    The is_protected rate, tower_height_m by tower_type and a breakdown of owner. Excel, Power BI or Tableau.

  • Why do the 52 lattice rows have a mean tower_height_m of 41.4?

    A root-cause class exercise

    Hand out the rows and one question. The answer is in the data, not in the brief.

  • A software demo

    Believable lines with line_name, from_substation and to_substation to fill a screen in front of a buyer.

Not quite right?

Make it yours.

Same 21 columns, your size and your rules. See 20 rows before you pay.

Preview 20 rows free

1,000 rows: $1.99 · 10,000: $12.99One-time. No subscription. All prices

This dataset100 rows21 columns
Yours1,000 rows21 columns

blueprint · transmission-lines-and-conductors

Behind this dataset

Same schema. As many rows as you need.

These 100 rows came out of a blueprint — 21 columns with generation rules behind each one. Open it in Data Factory to retune a column, add your own, wire in foreign keys, and run it at the size you actually need.

Rules it was built with
  • Line ID unique per circuit
  • From-bus and to-bus connections
  • Voltage level and number of circuits (single, double)
  • Line length in miles or kilometers
  • Conductor type: ACSR, ACAR, ACSS, HTLS
  • Positive and zero sequence impedance (R, X, B)
  • Thermal ratings: normal, emergency, winter, summer (MVA or Amps)
  • Ampacity based on conductor temperature limits
Rows
Open the blueprint in Data Factory

1 credit per row. Preview 20 rows free. Buy rows for the full run.

Exports
CSV, JSON, JSONL, Parquet, SQL, Excel, TSV, XML
Licence
yours to use, including commercially
API slug
transmission-lines-and-conductors

What should your data show?

Preview 20 rows free
No signup. No card.